OSHA Inspection: AMAK TOWING COMPANY, INC.

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of AMAK TOWING COMPANY, INC. in P.O. BOX 7655, KETCHIKAN, AK 99901 (NAICS 488320). OSHA activity number 335011383.

Watch Amak Towing Company, INC. — free Get an email when a new federal OSHA severe-injury report for Amak Towing Company, INC. is published. One employer, no account, unsubscribe in one click.
Site address
P.O. BOX 7655
City
KETCHIKAN
State
AK
ZIP
99901
Mailing
P.O. BOX 7655, KETCHIKAN, AK 99901
Inspection type
Unprogrammed Other (I)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
488320
Employees
35
Ownership type
A

2 citations on file for this inspection.

1910.305 G02 III

Serious Gravity 1 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $2550.00 · Current $1530.00 Reduced
29 CFR 1910.305(g)(2)(iii):     Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws:    Saxman (Welding shop area):  120 volt black extension cord by locally manufactured floor grinder had cord had its plug conductors exposed due damaged strain relief. This exposed employees to an electrical shock hazard.
Recent events (2)
  • — I (S) $1530
  • — Z (S) $2550

1910.334 A02 I

Serious Gravity 1 3 instances 5 exposed
Issued
Penalty
Initial $2100.00 · Current $1260.00 Reduced
29 CFR 1910.334(a)(2)(i):     Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket):    a)  AMAK Warehouse Area:  On or about 28 June 2012 and times prior thereto, the 120 volt, Milwaukee vacuum cleaner's electrical plug was missing the ground pin.  This exposed employees to electrical shock hazards.      b)  AMAK Warehouse Area:  On or about 28 June 2012 and times prior thereto, the 120 volt, Paint shaker cord had exposed wires. This exposed employees to electrical shock hazards.      c)  Saxman Yard (Welding shop area):  On or about 28 June 2012 and times prior thereto, the 120 volt, Makita circular hand saw, 7 1/4" blade, Model # 5277NB (Ser # 00541377) had a damaged cord. The electrical cord was taped with black electrical tape.  This exposed employees to electrical shock hazards.
Recent events (2)
  • — I (S) $1260
  • — Z (S) $2100

View AMAK TOWING COMPANY, INC.'s full OSHA safety record →