KETCHIKAN, AK —
OSHA Inspection: SOUTHEAST STEVEDORING INC.
Unprogrammed Other inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Other safety inspection of SOUTHEAST STEVEDORING INC. in P.O. BOX 8080, KETCHIKAN, AK 99901 (NAICS 488320). OSHA activity number 335013181.
Where did this inspection happen?
- Establishment
- SOUTHEAST STEVEDORING INC.
- Site address
- P.O. BOX 8080
- City
- KETCHIKAN
- State
- AK
- ZIP
- 99901
- Mailing
- P.O. BOX 8080, KETCHIKAN, AK 99901
What kind of inspection was it?
- Inspection type
- Unprogrammed Other (I)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 488320
- Employees
- 25
- Ownership type
- A
Citations
5 citations on file for this inspection.
1917.151 G01
- Issued
- Abate by
- Penalty
- Initial $1360.00 · Current $816.00 Reduced
General-duty citation text
29 CFR 1917.151(g)(1): Safety guards for abrasive wheels were not adjustable or did not have an adjustable tongue or piece at the top of the opening where the operator must stand in front of the safety guard opening. AMAK Warehouse (Maintenance area): On or about 28 June 2012 and times prior thereto, the Baldor F1075 Grinder, serial #G7-171-30, was missing the tongue guard. The equipment was plugged into the 120 volt, electrical outlet. This exposed employees to struck by hazards.
Recent events (2)
- — I (S) $816
- — Z (S) $1360
1917.151 G04
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1917.151(g)(4): Work rests on fixed grinding machines were not adjusted closely to the wheel with a maximum opening of 1/8-inch (3.18 mm) and securely clamped. AMAK Warehouse (Maintenance area): On or about 28 June 2012 and times prior thereto, the Baldor F1075 Grinder, serial # G7-171-30, work rest was unsecured. This exposed employees to struck by and caught in hazards.
Recent events (1)
- — Z (S) $0
1917.151 H01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1917.151(h)(1): Rotating parts such as gears and pulleys located 7 feet (2.13 m) or less above working surfaces were not guarded to prevent employee contact with moving parts. Saxman Yard (welding Shop area): On or about 28 June 2012 and times prior thereto, the locally manufactured grinder adjacent to the Miller welding unit, had exposed belts and pulleys. The grinder was plugged into a 120 volt electrical outlet. This exposed employees to pinch hazards.
Recent events (1)
- — Z (S) $0
1917.152 E02 II
- Issued
- Abate by
- Penalty
- Initial $1360.00 · Current $816.00 Reduced
General-duty citation text
29 CFR 1917.152(e)(2)(ii): Arc welding or cutting cable was used when it was not free from repair or splice for 10 feet (3 m) from the electrode holder. Saxman Yard (Welding shop area): On or about 28 June 2012 and times prior thereto, the Miller 250 Welding unit, Serial # KF825154, Stock # 903056, was connected to a stinger with a burnt hole that exposed wires of the lead. The exposed wires were 3 inches from the stinger and were improperly repaired with black electrical tape. This condition exposed employees to electrical shock hazards.
Recent events (2)
- — I (S) $816
- — Z (S) $1360
1917.152 C03
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1917.152(c)(3): Fire extinguishing equipment suitable for the location was not immediately available or maintained in readiness for use at all times during the performance of hot work. On or about 28 June 2012 and times prior thereto, the fire extinguishers at SaxmanYard were not inspected on a monthly basis. Stick welding operations were being conducted in the welding shop building. This exposed employees to smoke inhalation hazards in combatting fires.
Recent events (1)
- — Z (O) $0
More inspections at SOUTHEAST STEVEDORING INC.
KETCHIKAN, AK—2024-08-21 00:00:00
SOUTHEAST STEVEDORING INC.
KETCHIKAN, AK—2012-06-28 00:00:00
SOUTHEAST STEVEDORING INC.
KETCHIKAN, AK—2010-09-23 00:00:00
SOUTHEAST STEVEDORING INC.
KETCHIKAN, AK—1988-08-17 00:00:00
SOUTHEAST STEVEDORING, INC.
KETCHIKAN, AK—1988-06-14 00:00:00
SOUTHEAST STEVEDORING, INC.
View SOUTHEAST STEVEDORING INC.'s full OSHA safety record →
More inspections in this industry (NAICS 488320)
MARATHON, FL—2026-07-14
DISCOUNT ROCK & SAND, INC.
RIVIERA BEACH, FL—2026-07-07
PORT CONTRACTORS SOUTHEAST, LLC
JACKSONVILLE, FL—2026-07-01
CROWLEY LINER SERVICES
SEATTLE, WA—2026-06-30
WA317991873 - SSA TERMINALS LLC
TERMINAL ISLAND, CA—2026-06-10
YUSEN TERMINALS LLC
More inspections in AK
ANCHORAGE, AK—2026-07-10
AK, INC
ANCHORAGE, AK—2026-07-08
ONE STOP SERVICES
, AK—2026-07-08
ANGUS ENTERPRISES
ANCHORAGE, AK—2026-07-08
NORTHERN EXCAVATION & CONSTRUCTION, LLC
UNALASKA, AK—2026-07-07
UNISEA INC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 335013181.