PORT ARTHUR, TX —
OSHA Inspection: DME INDUSTRIAL LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of DME INDUSTRIAL LLC in 2450 S. GULFWAY DR, PORT ARTHUR, TX 77641 (NAICS 541990). OSHA activity number 335030987.
Where did this inspection happen?
- Establishment
- DME INDUSTRIAL LLC
- Site address
- 2450 S. GULFWAY DR
- City
- PORT ARTHUR
- State
- TX
- ZIP
- 77641
- Mailing
- 13123 W. PORT ARTHUR ROAD, BEAUMONT, TX 77705
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 541990
- Employees
- 95
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.119 H02 IV
- Issued
- Penalty
- Initial $2800.00 · Current $2800.00
General-duty citation text
29 CFR 1910.119(h)(2)(iv): The employer did not develop and implement safe work practices consistent with paragraph (f)(4) of this section, to control the entrance, presence and exit of contract employers and contract employees in covered process areas. -In the Alternative- 29 CFR 1910.147(d)(5)(ii): When there was a possibility of reaccumulation of stored energy to a hazardous level, verification of isolation was not continued until the servicing or maintenance was completed, or until the possibility of such accumulation no longer exists. This violation was most recently observed at KMTEX in Port Arthur, TX, in the ISOM Unit, when the employer did not ensure that the procedures to isolate and deinventory (lockout/tagout procedures) were effective in the continuation in the verification of isolation, when employees introduced plant nitrogen into the plumber's plug, while DME employees were performing maintenance on the Hot Oil line during the Biodiesel expansion project.
Recent events (1)
- — Z (S) $2800
1910.147 C04 II
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.147(c)(4)(ii): The procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance. This condition was most recently observed at KMTEX in Port Arthur, TX, in the ISOM Unit, when the employer did not ensure that the energy control procedures clearly and specifically outline the techniques to be utilized for the control of nitrogen pressure when the employees introduced the nitrogen into the test plug/plumbers plug, when performing maintenance on the 10 inch pipe on the hot oil line for the Biodiesel Project.
Recent events (1)
- — Z (S) $0
1910.147 F03 I
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.147(f)(3)(i): When servicing and/or maintenance was performed by a crew, craft, department or other group, they did not utilize a procedure which affords the employees a level of protection equivalent to that provided by the implementation of a personal lockout or tagout device. This condition was most recently observed at KMTEX in Port Arthur, TX, when the employer, did not ensure that all employees in the ISOM Unit utilized a Lockout/Tagout procedure that afforded the employees a level of protection equivalent to protection provided by the implementation of a personal lockout or tagout device, when performing maintenance on the 10 inch pipe of the hot oil line for the Biodiesel Project.
Recent events (1)
- — Z (S) $0
1910.119 J06 II
- Issued
- Penalty
- Initial $2800.00 · Current $2800.00
General-duty citation text
29 CFR 1910.119(j)(6)(ii): Appropriate checks and inspections were not performed to assure that equipment was installed properly and consistent with design specifications and the manufacturer's instructions. This condition was most recently observed at KMTEX in Port Arthur, TX, in the ISOM Unit, when the employer exceeded the maximum allowable backpressure to be applied to the test plugs/plumbers plugs, with plant nitrogen, during the maintenance tie in of the Biodiesel Project which was not consistent with design specifications and manufacturers instructions.
Recent events (1)
- — Z (S) $2800
More inspections in this industry (NAICS 541990)
AVALON, CA—2026-04-23 00:00:00
CATALINA ISLAND COMPANY
FORT MADISON, IA—2026-04-15 00:00:00
A09CS00000TXLUFAA4 - WAGGONER SOLUTIONS CO.
HOUSTON, TX—2026-04-14 00:00:00
SAFETY MANAGEMENT SYSTEMS
BOCA RATON, FL—2026-03-27 00:00:00
ALL 1 SERVICE, INC
FLORENCE, NJ—2026-03-25 00:00:00
MUMFORD-BJORKMAN ASSOCIATES, INC.
More inspections in TX
WICHITA FALLS, TX—2026-07-16 00:00:00
UNITED RENTALS, INC.
SAN MARCOS, TX—2026-07-16 00:00:00
CASA MECHANICAL SERVICES, LTD.
CLARKSVILLE, TX—2026-07-15 00:00:00
SEQUOIAS TREE EXPERT LLC
EL PASO, TX—2026-07-15 00:00:00
SURE STEEL
CORPUS CHRISTI, TX—2026-07-15 00:00:00
NORTH STAR ENERGY SOLUTIONS LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 335030987.