OSHA Inspection: L & M MANUFACTURING COMPANY, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of L & M MANUFACTURING COMPANY, INC. in 37 GREENWOODS ROAD, NEW HARTFORD, CT 06057 (NAICS 332722). OSHA activity number 335090387.

Watch L & M Manufacturing Company, INC. — free Get an email when a new federal OSHA severe-injury report for L & M Manufacturing Company, INC. is published. One employer, no account, unsubscribe in one click.
Site address
37 GREENWOODS ROAD
City
NEW HARTFORD
State
CT
ZIP
06057
Mailing
P.O. BOX 294, NEW HARTFORD, CT 06057
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332722
Employees
8
Ownership type
A

3 citations on file for this inspection.

1910.212 A03 II

Serious Gravity 5 6 instances 2 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $500.00 Reduced
29 CFR 1910.212(a)(3)(ii):  Point of operation guards were not designed and constructed as to prevent the operator from having any part of their body in the danger zone during the operating cycle:      Production:  Cold headers were not safeguarded in accordance with American National Standard Institute (ANSI) B11.7, "Cold Headers and Cold Formers - Safety Requirements for Construction, Care, and Use," in that:      A.  The interlock to the guard was bypassed while in run mode on the Ayase Seiki Co., Type ASOOHTR, Number 12081 header.    B.  The following equipment was operated without the ram guard interlocked:         1.  Asahi Okuma, Machine T-48-1187       2.  National Four Die       3.  Nakashimada N E W H-20A 7906252    C.  The Asahi Okuma, Machine T-48-1187 was operated without the hood guard interlocked.    D.  The hood guard was not secured on the National Four Die header.    E.  The National Four Die header was provided with a single jog button for setup operation.    F.  The company did not provide spring loaded turnover bars which would prevent them from being left in the flywheel.    G.  The company did not have established written die setting procedures for the header setup.    H.  The employer did not provide die blocks for use during setup.
Recent events (3)
  • — C (S) $2000
  • — F (S) $500
  • — Z (S) $2000

1910.304 G05

Serious Gravity 1 1 instance 8 exposed
Issued
Abate by
Penalty
Initial $1200.00 · Current $500.00 Reduced
29 CFR 1910.304(g)(5):  The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective:          Outside Maintenance Shop:  Dayton 26" pedestal fan was not grounded, exposing employees to electric shock hazards.
Recent events (3)
  • — C (S) $1200
  • — F (S) $500
  • — Z (S) $1200

1910.242 B

Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.242(b):   Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.:          Tool bench at the Waterbury 10 machine "W2":  Compressed air used for cleaning was not reduced to below 30 p.s.i.
Recent events (3)
  • — C (O) $0
  • — F (O) $0
  • — Z (O) $0