SYRACUSE, NY —
OSHA Inspection: TITAN NORTH AMERICA INC.
Unprogrammed Related inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Related safety inspection of TITAN NORTH AMERICA INC. in 306 HIAWATHA BLVD WEST DESTINY USA, SYRACUSE, NY 13204 (NAICS 236220). OSHA activity number 335299384.
Where did this inspection happen?
- Establishment
- TITAN NORTH AMERICA INC.
- Site address
- 306 HIAWATHA BLVD WEST DESTINY USA
- City
- SYRACUSE
- State
- NY
- ZIP
- 13204
- Mailing
- 77460 LANCASTER PIKE #7, HOCKESSIN, DE 19707
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236220
- Employees
- 2
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.34 A
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $1000.00 Reduced
General-duty citation text
29 CFR 1926.34(a): Every building or structure exit was not arranged and maintained as to provide free and unobstructed egress from all parts of the building or structure at all times when it was occupied: a) On or about 7/11/2012, "Ecko" Store: The rear exit from the store was secured shut with angle brackets and screws.
Recent events (3)
- — J (O) $1000
- — C (S) $2000
- — Z (S) $2000
1926.404 F06
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous: a) On or about 7/11/2012, "Ecko" Store: A metal cased light fixture was not provided with a path to ground as its ground pin was missing. Abatement certification is required for this item.
Recent events (3)
- — J (O) $0
- — C (O) $0
- — Z (O) $0
1926.405 G02 IV
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws: a) On or about 7/11/2012, "Ecko" Store: Extension cords were in use with damaged insulation which eliminated the strain relief. Abatement certification is required for this item.
Recent events (3)
- — F (O) $0
- — C (O) $0
- — Z (O) $0
More inspections at TITAN NORTH AMERICA INC.
FORESTVILLE, MD—2018-05-21 00:00:00
TITAN NORTH AMERICA, INC.
View TITAN NORTH AMERICA INC.'s full OSHA safety record →
More inspections in this industry (NAICS 236220)
IRVINE, CA—2026-07-13
SNEARY CONSTRUCTION, INC.
IRVINE, CA—2026-07-13
KUKBO DESIGN USA LLC
SIOUX FALLS, SD—2026-07-13
REM CONSTRUCTION SERVICES, LLC
INDIAN ROCKS BEACH, FL—2026-07-10
UNKNOWN CONTRACTOR
SIOUX FALLS, SD—2026-07-10
HENRY CARLSON COMPANY
More inspections in NY
POUGHKEEPSIE, NY—2026-07-13
MARCO BOARD HOUSE, INC.
CORTLANDT MANOR, NY—2026-07-13
LG BUILDERS INC.
CORTLANDT MANOR, NY—2026-07-13
RJW RENOVATIONS, LLC
HEMPSTEAD, NY—2026-07-13
NYSDOCCS NASSAU AREA OFFICE
NIAGARA FALLS, NY—2026-07-10
NTVI FEDERAL INC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 335299384.