Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: DESTINY USA, LLC

Unprogrammed Related inspection · Safety discipline

On , OSHA opened an unprogrammed Related safety inspection of DESTINY USA, LLC in 306 HIAWATHA BLVD WEST DESTINY USA, SYRACUSE, NY 13204 (NAICS 541611). OSHA activity number 335315784.

Watch Destiny USA, LLC — free Get an email when a new federal OSHA severe-injury report for Destiny USA, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
DESTINY USA, LLC
Site address
306 HIAWATHA BLVD WEST DESTINY USA
City
SYRACUSE
State
NY
ZIP
13204
Mailing
9090 DESTINY USA DRIVE, SYRACUSE, NY 13204
Inspection type
Unprogrammed Related (G)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
541611
Employees
10
Ownership type
A

2 citations on file for this inspection.

1926.56 A

Other-than-serious 2 instances 25 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $2800.00
29 CFR 1926.56(a): General. Construction areas, ramps, runways, corridors, offices, shops, and storage areas shall be lighted to not less than the minimum illumination intensities listed in Table D-3 while any work is in progress:        a) On or about 7/17/2012, All levels of Stairwell #8:  No lights were on in the marked exit stairway and work access way.      b) On or about 7/17/2012, Second floor hallway behind the Eddie Bauer Store:  No lights were on in the marked exit way.      Abatement certification is required for this item.
Recent events (3)
  • — J (O) $2800
  • — C (S) $2800
  • — Z (S) $2800

1926.404 B01 II

Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2100.00 · Current $2100.00
29 CFR 1926.404(b)(1)(ii): Ground-fault circuit interrupters. All 120-volt, single-phase 15- and 20-ampere receptacle outlets on construction sites, which are not a part of the permanent wiring of the building or structure and which are in use by employees, shall have approved ground-fault circuit interrupters for personnel protection. Receptacles on a two-wire, single-phase portable or vehicle-mounted generator rated not more than 5kW, where the circuit conductors of the generator are insulated from the generator frame and all other grounded surfaces, need not be protected with ground-fault circuit interrupters.    a) On or about 7/17/2012, First Floor Tree Production Area:  Electrical tools were energized through extension cords, no GFCIs or assured equipment grounding program were in use.          Abatement certification is required for this item.
Recent events (3)
  • — J (O) $2100
  • — C (S) $2100
  • — Z (S) $2100

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 335315784.