ROUND ROCK, TX —
OSHA Inspection: GUILLERMO SALVADOR
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of GUILLERMO SALVADOR in 1921 AUTUMN RUN LANE, ROUND ROCK, TX 78665 (NAICS 238160). OSHA activity number 335456992.
Where did this inspection happen?
- Establishment
- GUILLERMO SALVADOR
- Site address
- 1921 AUTUMN RUN LANE
- City
- ROUND ROCK
- State
- TX
- ZIP
- 78665
- Mailing
- 1513 GRAEF ROAD, UNIT# B, KYLE, TX 78640
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 6
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.102 A01
- Issued
- Abate by
- Penalty
- Initial $1200.00 · Current $700.00 Reduced
General-duty citation text
29 CFR 1926.102(a)(1): Employees shall be provided with eye and face protection equipment when machines or operations present potential eye or face injury from physical, chemical, or radiation agents. On or about 30 July 2012, and at times prior thereto, two employees were utlizing a pneumatic nail gun to nail in shingles on the roof of a two-story house under construction without the use of safety glasses, exposing the employees to the hazard of being struck by flying objects. Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the date of this citation, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure workers have and utilize safety glasses while operating nail guns or other tools that can cause flying materials.
Recent events (2)
- — I (S) $700
- — Z (S) $1200
1926.501 B11
- Issued
- Penalty
- Initial $1600.00 · Current $1000.00 Reduced
General-duty citation text
29 CFR 1926.501(b)(11): "Steep roofs." Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels shall be protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems. On or about 30 July 2012, and at times prior thereto, three employees were working on elevated surfaces at heights above 6 feet high, and on steep roofs with a pitch of 6 to 12, without the use of fall protection, exposing the employees to fall hazards of approximately 10.5 feet or more to the ground below. A) At the residence under construction located at 1915 Autumn Run Lane, two employees were performing roofing activities on the second story roof with a pitch of 6 to 12, without the use of fall protection. The first floor roof eave to ground measured at approximately 127 inches or ~10.5 feet. B) At the residence under construction located at 1921 Autumn Run Lane, one employee was performing roofing activities on a roof with a pitch of 6 to 12, without the use of fall protection. The roof eave to ground measured at approximately 125 inches or ~10.5 feet. Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the date of this citation, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure workers are protected from falling while working on steep sloped roofs that are above 6 feet in height.
Recent events (2)
- — I (S) $1000
- — Z (S) $1600
1926.1053 B01
- Issued
- Penalty
- Initial $1600.00 · Current $1000.00 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed. On or about 30 July 2012, and at times prior thereto, an employee was accessing the roof of a residence under construction to perform roofing activities using an aluminum 20-foot extension ladder that was not extended at least 3 feet above the upper landing, exposing the employee to a fall hazard of approximately 10.5 feet. Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the date of this citation, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure ladders are extended at least 3 feet above the upper landing.
Recent events (2)
- — I (S) $1000
- — Z (S) $1600
More inspections in this industry (NAICS 238160)
PORTLAND, OR—2026-07-17 00:00:00
317744797 - JBC ROOFING LLC
MERIDIAN, ID—2026-07-17 00:00:00
COBRA'S ROOFING LLC
SYRACUSE, NY—2026-07-17 00:00:00
NAMICELA HOME SOLUTIONS INC
BRADLEY, IL—2026-07-16 00:00:00
JUAN CRUZ DBA ROOFBOYS LLC
PONCE INLET, FL—2026-07-16 00:00:00
RESOLUTE ROOFING LLC
More inspections in TX
RICHMOND, TX—2026-07-17 00:00:00
CORNELIUS NURSERIES, INC.
HOUSTON, TX—2026-07-17 00:00:00
HOLLOWAY HOUSTON, INC.
BONHAM, TX—2026-07-17 00:00:00
VOLUNTARY PURCHASING GROUPS, INC.
SNYDER, TX—2026-07-16 00:00:00
RNWBL
WICHITA FALLS, TX—2026-07-16 00:00:00
UNITED RENTALS, INC.
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 335456992.