VAN BUREN, MO —
OSHA Inspection: BIG SPRING SHELTERED WORKSHOP
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of BIG SPRING SHELTERED WORKSHOP in HCR 2 BOX 2690C, VAN BUREN, MO 63965 (NAICS 321999). OSHA activity number 335560389.
Where did this inspection happen?
- Establishment
- BIG SPRING SHELTERED WORKSHOP
- Site address
- HCR 2 BOX 2690C
- City
- VAN BUREN
- State
- MO
- ZIP
- 63965
- Mailing
- HCR 2 BOX 2690C, VAN BUREN, MO 63965
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 321999
- Employees
- 24
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.212 A01
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $1400.00 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a/ Inside of the saw shop, the chuck and unused bit belonging to a Grizzly Industrial Drilling Machine, m/n G7943/44, s/n 15544, were unguarded.
Recent events (2)
- — I (S) $1400
- — Z (S) $2000
1910.213 P01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.213(p)(1): Feed rolls of self-feed sanding machine(s) were not protected with semicylindrical guard to prevent the hands of the operator from coming in contact with the in-running rolls: a/ Inside of the saw shop, the back stop belonging the Grizzly 4"X36"X6" Disc Combo Sander, m/n 200005, s/n 11008, was missing. Employees using this tool were exposed to the in-running roll.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 C05 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.147(c)(5)(i): Locks, tags, chains, wedges, key blocks, adapter pins, self-locking fasteners, or other hardware were not provided by the employer for isolating, securing or blocking of machines or equipment from energy sources: a/ A means of isolating the 220 volt electrical power at the circuit breaker panel for the MAX-PAX Vertical Baler, unknown m/n or s/n, was not available to the "authorized employee".
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 321999)
LAURINBURG, NC—2026-07-14 00:00:00
161549 - AMERICAN WOOD FIBERS, INC.
NEWINGTON, CT—2026-07-14 00:00:00
TRUSS MANUFACTURING INC
NORTH WILKESBORO, NC—2026-07-07 00:00:00
161501 - MILLER BEE SUPPLY, INC.
MIAMI, FL—2026-06-26 00:00:00
FLORIDA LUMBER COMPANY
PLATO, MN—2026-06-25 00:00:00
111471 - STEVE TUSHA DBA GREAT OAK EQUINE
More inspections in MO
SAINT LOUIS, MO—2026-07-17 00:00:00
UNITED PARCEL SERVICE
PLATTE CITY, MO—2026-07-15 00:00:00
TRIPLE J CONSTRUCTION, LLC.
CLINTON, MO—2026-07-14 00:00:00
TORCHYLO BUILDERS, LLC.
BLUE SPRINGS, MO—2026-07-13 00:00:00
JORGE MERIDA
KANSAS CITY, MO—2026-07-09 00:00:00
NIAGARA BOTTLING
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 335560389.