WINNECONNE, WI —
OSHA Inspection: MENATOR METAL WORKS LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of MENATOR METAL WORKS LLC in 205 W. ENTERPRISE DRIVE, WINNECONNE, WI 54986 (NAICS 332312). OSHA activity number 335563789.
Where did this inspection happen?
- Establishment
- MENATOR METAL WORKS LLC
- Site address
- 205 W. ENTERPRISE DRIVE
- City
- WINNECONNE
- State
- WI
- ZIP
- 54986
- Mailing
- 205 W. ENTERPRISE DRIVE, WINNECONNE, WI 54986
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332312
- Employees
- 5
- Ownership type
- A
Citations
7 citations on file for this inspection.
1910.178 L02 II
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $2000.00
General-duty citation text
29 CFR 1910.178(l)(2)(ii): The employer did not ensure that each operator had successfully completed the training consisting of a combination of formal instruction (e.g., lecture, discussion, interactive computer learning, video tape, written material), practical training (demonstrations performed by the trainer and practical exercises performed by the trainee), and evaluation of the operator's performance in the workplace. (a) The employer did not provide any formal training to forklift operators or evaluate operators' performance. ABATEMENT CERTIFICATION AND DOCUMENTATION REQUIRED
Recent events (1)
- — Z (S) $2000
1910.178 L06
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.178(l)(6): The employer did not certify that each operator has been trained and evaluated as required by this paragraph (l): (a) The employer did not perform training for forklift operators or document employees' training from previous employment. ABATEMENT CERTIFICATION AND DOCUMENTATION REQUIRED
Recent events (1)
- — Z (S) $0
1910.212 A01
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $2000.00
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: (a) An Ellis belt grinder did not have ingoing nip points protected between the belt and wheel. NO ABATEMENT CERTIFICATION AND DOCUMENTATION REQUIRED
Recent events (1)
- — Z (S) $2000
1910.243 C03
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $2000.00
General-duty citation text
29 CFR 1910.243(c)(3): Abrasive wheels used on vertical portable grinder(s) (right angle head grinders) were not provided with safety guard(s) having a maximum exposure angle of 180 degrees and located between the operator and wheel: (a) Metabo die grinder with a vertical abrasive wheel did not have a guard on it, exposing 360 degrees of the grinding wheel. ABATEMENT CERTIFICATION AND DOCUMENTATION REQUIRED
Recent events (1)
- — Z (S) $2000
1910.243 C04
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.243(c)(4): The angular exposure on the grinding wheel periphery and sides for safety guard(s) used on portable grinding machine(s) exceeded 180 degrees: (a) Employees using an Angle grinder for cleaning up metal parts did not have any guard on it, exposing 360 degrees of the grinding wheel. NO ABATEMENT CERTIFICATION OR DOCUMENTATION REQUIRED
Recent events (1)
- — Z (S) $0
1910.305 G02 III
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $2000.00
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws: (a) A flexible cord powering the plasma cutter near the garage door did not utilize proper strain relief, allowing the insulation to be pulled back, exposing the conductors. NOTE: KNOTS IN CORDS, WINDING WITH TAPE, SPECIAL FITTINGS OR OTHER APPROVED MEANS OF CONNECTION ARE ACCEPTABLE (NEC 40010) NO ABATEMENT CERTIFICATION OR DOCUMENTATION REQUIRED
Recent events (1)
- — Z (S) $2000
1910.334 A02 II
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.334(a)(2)(ii): There was a defect or evidence of damage that could have exposes an employee to injury and the defective or damaged item was not removed from service: (a) An extension cord used to power a welder has damaged insulation revealing the conductors. NO ABATEMENT CERTIFICATION AND DOCUMENTATION REQUIRED
Recent events (1)
- — Z (S) $0
More inspections in this industry (NAICS 332312)
WYOMING, MI—2026-07-16 00:00:00
R&M FABRICATION LLC
TRUSSVILLE, AL—2026-07-16 00:00:00
ALL SOUTH STEELWORX, LLC
NORTH BRANCH, MN—2026-07-15 00:00:00
111603 - BROWN HAWK LLC DBA NORTHERN LIGHTS STEEL FAB
VAN BUREN, AR—2026-07-14 00:00:00
MILLAR PARTNERS, LLC
CLANTON, AL—2026-07-14 00:00:00
C & S CANOPY, INC.
More inspections in WI
GREEN BAY, WI—2026-07-17 00:00:00
PTS CONTRACTORS, INC.
WAUSAU, WI—2026-07-16 00:00:00
MIRON CONSTRUCTION CO. INC.
ELROY, WI—2026-07-15 00:00:00
WABASH NATIONAL SERVICES, L.P.
SUSSEX, WI—2026-07-15 00:00:00
KINGS SUPERIOR CONSTRUCTION LLC
DELAVAN, WI—2026-07-15 00:00:00
TERONOMY BUILDERS, INC.
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 335563789.