MIDLAND, TX —
OSHA Inspection: BISON DRILLING & FIELD SERVICES
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of BISON DRILLING & FIELD SERVICES in KEMMER LEASE, WELL #4209H, BISON RIG #62 10.18 MILES W. FROM MIDLAND, TX, MIDLAND, TX 79707 (NAICS 213111). OSHA activity number 335582011.
Where did this inspection happen?
- Establishment
- BISON DRILLING & FIELD SERVICES
- Site address
- KEMMER LEASE, WELL #4209H, BISON RIG #62 10.18 MILES W. FROM MIDLAND, TX
- City
- MIDLAND
- State
- TX
- ZIP
- 79707
- Mailing
- 14301 CALIBER DR. SUITE 300, MIDLAND, TX 79707
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 213111
- Employees
- 22
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.23 C01
- Issued
- Abate by
- Penalty
- Initial $3080.00 · Current $1848.00 Reduced
General-duty citation text
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent) and toeboards: On or about August 3, 2012, the bar silo platform next to the mud house was missing all handrails around the platform where employees work. This condition exposed the employees to a fall hazard of approximately 12 feet to the ground.
Recent events (2)
- — I (S) $1848
- — Z (S) $3080
1910.132 A
- Issued
- Abate by
- Penalty
- Initial $3850.00 · Current $2310.00 Reduced
General-duty citation text
29 CFR 1910.132(a): Protective equipment was not used when necessary whenever hazards capable of causing injury and impairment were encountered: On or about August 3, 2012, the employees on Bison Rig #62 were not wearing FRCs while drilling through hydrocarbon zones. This condition exposed the employees to a fire hazard.
Recent events (2)
- — I (S) $2310
- — Z (S) $3850
1910.151 C
- Issued
- Abate by
- Penalty
- Initial $3850.00 · Current $1925.00 Reduced
General-duty citation text
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use: On or about August 3, 2012, the employer failed to maintain a working eyewash machine and a shower. This condition exposed the employees to serious burns and damage to the eyes and body. 1. Eyewash machine on mud pit was inoperable. 2. Shower on shaker pit had no water.
Recent events (2)
- — I (O) $1925
- — Z (S) $3850
1910.176 B
- Issued
- Abate by
- Penalty
- Initial $4620.00 · Current $2772.00 Reduced
General-duty citation text
29 CFR 1910.176(b): Material stored in tiers was not stacked, blocked, interlocked or limited in height so that it was stable and secure against sliding and collapse: On or about August 3, 2012 the pipe stacked to the right of the catwalk at Bison Rig #62 was not chocked or pinned on either side of the pipes. This condition is exposing the employees to struck-by/caught-in-between hazards.
Recent events (2)
- — I (S) $2772
- — Z (S) $4620
1910.212 A01
- Issued
- Abate by
- Penalty
- Initial $5390.00 · Current $3234.00 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: On or about August 3, 2012, the drawworks on the rig floor of Bison Rig #62 was being used without a side guard. This condition exposed the employees to caught-in-between and pinch-by hazards.
Recent events (2)
- — I (S) $3234
- — Z (S) $5390
1910.304 G05
- Issued
- Abate by
- Penalty
- Initial $5390.00 · Current $2000.00 Reduced
General-duty citation text
29 CFR 1910.304(g) (5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective: On or about August 3, 2012, the grounding rods at several locations on Bison Rig #62 were not properly installed; the ground rods were not inserted into the earth by NEC standards. This condition exposed the employees to electrical hazards. 1. Rig Managers trailer 2. Shaker Pit
Recent events (2)
- — I (O) $2000
- — Z (S) $5390
More inspections at BISON DRILLING & FIELD SERVICES
MIDLAND, TX—2014-07-30 00:00:00
BISON DRILLING & FIELD SERVICES
View BISON DRILLING & FIELD SERVICES's full OSHA safety record →
More inspections in this industry (NAICS 213111)
JAL, NM—2026-07-01
HELMERICH & PAYNE, IDC
LAREDO, TX—2026-06-28
AXIS ENERGY SERVICES
MCALESTER, OK—2026-06-18
SANGUINE GAS EXPLORATION, LLC
MOUNT PLEASANT, MI—2026-06-15
BIGARD & HUGGARD DRILLING INC
MOUNT PLEASANT, MI—2026-06-15
BIGARD & HUGGARD DRILLING INC
More inspections in TX
SPRING, TX—2026-07-10
DORSTENER WIRE TECH INC.
FORT WORTH, TX—2026-07-10
RC PROFESSIONAL ROOFING OF TEXAS LLC
CYPRESS, TX—2026-07-10
FEDERICO CARVAJAL GARCIA
SAN ANTONIO, TX—2026-07-10
ED LONG'S METAL WORKS
SAN ANTONIO, TX—2026-07-09
WAREHOUSE RACK COMPANY, LP
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 335582011.