On , OSHA opened a referral safety inspection of PREFERRED DRYWALL BY MCDOWELL & ARIAIL, INC. in 4210 UNIVERSITY AVE, JACKSONVILLE, FL 32216 (NAICS 238310). OSHA activity number 335589396.
Where did this inspection happen?
- Establishment
- PREFERRED DRYWALL BY MCDOWELL & ARIAIL, INC.
- Site address
- 4210 UNIVERSITY AVE
- City
- JACKSONVILLE
- State
- FL
- ZIP
- 32216
- Mailing
- 2332 DUNN AVE, JACKSONVILLE, FL 32218
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238310
- Employees
- 5
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.451 B01
- Issued
- Penalty
- Initial $2800.00 · Current $1500.00 Reduced
General-duty citation text
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii): a. On or about August 6, 2012, on the north side of the building, the scaffold was not fully planked, exposing an employee to a 13 feet fall hazard. b. On or about August 6, 2012, on the south side of the building, the scaffold was not fully planked, exposing an employee to a 16 feet fall hazard.
Recent events (2)
- — I (S) $1500
- — Z (S) $2800
1926.451 G01
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section: a. On or about August 6, 2012, on the north side of the building, the scaffold did not have a guardrail system, exposing an employee to a 13 feet fall hazard. b. On or about August 6, 2012, on the south side of the building, the scaffold did not have a guardrail system, exposing an employee to a 16 feet fall hazard.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 F07
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration; Such activities were not performed only by experienced and trained employees selected for such work by the competent person: a. On or about August 6, 2012, on the north side of the building, the scaffold was not erected under the supervision of a competent person. b. On or about August 6, 2012, on the north side of the building, the scaffold was not erected under the supervision of a competent person.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.501 B01
- Issued
- Penalty
- Initial $2800.00 · Current $1500.00 Reduced
General-duty citation text
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems: a. On or about August 6, 2012, on the south side of the building, an employee installing metal framing on the edge of the parapet wall was not protected from a 19 feet fall hazard by the use of a fall protection system.
Recent events (2)
- — I (S) $1500
- — Z (S) $2800
1926.451 C02
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, or uprights did not bear on base plates, mud sills or other adequate firm foundation: a. On or about August 6, 2012, on the north side of the building, one leg of the scaffold did not have base plates or mudsills.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 238310)
HENDERSON, NV—2026-07-16 00:00:00
ROADRUNNER DRYWALL CORPORATION
BANNOCKBURN, IL—2026-07-16 00:00:00
BUILDER SERVICES GROUP, INC. DBA CJ INSULATION
NAMPA, ID—2026-07-15 00:00:00
INTERIOR SYSTEMS, INC.
BRIDGEPORT, WV—2026-07-14 00:00:00
EASLEY & RIVERS, INC.
ELLETTSVILLE, IN—2026-07-13 00:00:00
ENVIRO HEAT, LLC
More inspections in FL
DELAND, FL—2026-07-16 00:00:00
BALL FABRICS
GAINESVILLE, FL—2026-07-16 00:00:00
WACKY SAUCES LLC
FORT WALTON BEACH, FL—2026-07-16 00:00:00
WASTE MANAGEMENT, INC. OF FLORIDA
PONCE INLET, FL—2026-07-16 00:00:00
RESOLUTE ROOFING LLC
PALM COAST, FL—2026-07-16 00:00:00
J & J TREE EXPERTS, INC.
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 335589396.