2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: PIONEER ROOFING, LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of PIONEER ROOFING, LLC in 6813 - 6845 IRVING ST, BOISE, ID 83706 (NAICS 238160). OSHA activity number 335807996.

Watch Pioneer Roofing, LLC — free Get an email when a new federal OSHA severe-injury report for Pioneer Roofing, LLC is published. One employer, no account, unsubscribe in one click.
Site address
6813 - 6845 IRVING ST
City
BOISE
State
ID
ZIP
83706
Mailing
2604 MUSKRAT AVE, NAMPA, ID 83687
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
3
Ownership type
A

2 citations on file for this inspection.

1926.102 A01

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $1200.00 · Current $600.00 Reduced
29 CFR 1926.102(a)(1):     Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents.    (a) East and west side of roof: On or about August 16, 2012 two employees using pneumatic Max nail guns to fix shingles to a residential roof had not been provided safety glasses.     Note: Abatement certification IS required.
Recent events (2)
  • — I (S) $600
  • — Z (S) $1200

1926.501 B13

Serious Gravity 5 2 instances 2 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $1000.00 Reduced
29 CFR 1926.501(b)(13):     Each employee engaged in residential construction activities 6 feet (1.8 m)  or more above lower levels was not protected by guardrail systems, safety net systems, personal fall arrest systems, or an alternative fall protection measure under another provision of paragraph 1926.501 (b), nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502:     (a) On or about August 16, 2012 an employee with no means of fall protection was installing shingles on the eastern side of a residential roof and was exposed to an approximate 21 foot fall hazard to ground below.      (b) On or about August 16, 2012 an employee with no means of fall protection was installing shingles on the western side of a residential roof and was exposed to an approximate 19 foot fall hazard to ground below.      Note: Abatement certification IS required.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2000

View PIONEER ROOFING, LLC's full OSHA safety record →