Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,645Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: JUAN DELALUZ

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of JUAN DELALUZ in 1091 -1105 CAMDEN CT, GLENDALE HEIGHTS, IL 60137 (NAICS 238160). OSHA activity number 335877783.

Watch Juan Delaluz — free Get an email when a new federal OSHA severe-injury report for Juan Delaluz is published. One employer, no account, unsubscribe in one click.
Establishment
JUAN DELALUZ
Site address
1091 -1105 CAMDEN CT
City
GLENDALE HEIGHTS
State
IL
ZIP
60137
Mailing
3436 W. 60TH PL, CHICAGO, IL 60629
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
7
Ownership type
A

2 citations on file for this inspection.

1926.501 B13

Serious Gravity 10 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $2800.00
29 CFR 1926.501(b)(13):     Employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph (b)    On or about August 22, 2012 employees were working on a roof performing roofing work without fall protection exposing employees to a fall hazard of 9.5 to 19.5 feet.    Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (1)
  • — Z (S) $2800

1926.1053 B01

Serious Gravity 5 3 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $2000.00
29 CFR 1926.1053(b)(1):     Because of the portable ladder's length, the ladder side rails did not extend to at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access.    On or about August 22, 2012 employees using a ladder that did not extend 3 feet above the level the employees were accessing exposing employees to a fall hazard of 9.5 feet.    Abatement certification is required of this item in accordance with the requirements of 29 CFR 1903.19(c).
Recent events (1)
  • — Z (S) $2000