Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,645Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: DONE SERVICE GROUP, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of DONE SERVICE GROUP, INC. in 10226 WOODROSE CT., HIGHLANDS RANCH, CO 80129 (NAICS 238220). OSHA activity number 335998191.

Watch Done Service Group, INC. — free Get an email when a new federal OSHA severe-injury report for Done Service Group, INC. is published. One employer, no account, unsubscribe in one click.
Site address
10226 WOODROSE CT.
City
HIGHLANDS RANCH
State
CO
ZIP
80129
Mailing
541 NORFOLK ST., AURORA, CO 80011
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238220
Employees
7
Ownership type
A

7 citations on file for this inspection.

1926.416 E01

Serious Gravity 1 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $1785.00 · Current $1000.00 Reduced
29 CFR 1926.416(e)(1): Worn or frayed electric cords or cables were used:    a)  On or about August 28, 2012, employees were exposed to electrical hazards while using an electric jackhammer where the insulation on the cord was damaged, exposing the conductor.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $1785

1926.651 I03

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $4900.00 · Current $2500.00 Reduced
29 CFR 1926.651(i)(3): Sidewalks, pavements, or appurtenant structures had been undermined and a support system or another method was not provided to protect employees from the possible collapse of such structures:    a)  On or about August 28, 2012, employees were not protected from injury in that, employees were working in an excavation under an overhanging slab of concrete that was not supported.
Recent events (2)
  • — I (S) $2500
  • — Z (S) $4900

1926.1053 B01

Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2100.00 · Current $1000.00 Reduced
29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access:    a)  On or about August 28, 2012, employees were exposed to falls while using a section of an extension ladder to access an excavation that did not extend at least 3 feet above the ground level.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2100

1926.200 G02

Deleted Serious Gravity 5 1 instance 6 exposed
Issued
Abate by
Penalty
Initial $3500.00 · Current $0.00 Reduced
29 CFR 1926.200(g)(2): Traffic control signs or devices used for protection of construction workers did not conform to Part VI of the Manual of Uniform Traffic Control Devices (AMUTCD"), 1988 Edition, Revision 3, September 3, 1993, FHWA-SA-94-027 or Part VI of the Manual on Uniform Traffic Control Devices, Millenium Edition, December 2000, FHWA:    a)  On or about August 28, 2012, employees were not protected from vehicular traffic hazards in that, no advance warning signs were placed on either side of the work area to alert motorists that work was taking place on the street.  Employees were also crossing the street and operating equipment in the street without adequate controls in place.  A traffic control plan had also not been developed.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3500

1926.651 J02

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $3500.00 · Current $3000.00 Reduced
29 CFR 1926.651(j)(2): Protection was not provided by placing and keeping excavated or other materials or equipment at least 2 feet (.61m) from the edge of excavations, or by the use of retaining devices that were sufficient to prevent materials or equipment from falling or rolling into excavations, or by a combination of both if necessary:    a)  On or about August 28, 2012, employees were not protected from injury in that, spoils were not set back and maintained at least 2 feet back from the edge of the excavation opr otherwise retained.
Recent events (2)
  • — I (S) $3000
  • — Z (S) $3500

1926.652 A01

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $4900.00 · Current $2500.00 Reduced
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652(c):    a)  On or about August 28, 2012, employees were not protected from cave-in hazards while performing sewer repair work in an excavation without the use of protective systems.
Recent events (2)
  • — I (S) $2500
  • — Z (S) $4900

1926.651 K01

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.651(k)(1): Daily inspections of excavations, the adjacent areas, and protective systems were not made by a competent person for evidence of a situation that could have resulted in possible cave-ins, indications of failure of protective systems    a)  On or about August 28, 2012, employees were not protected from injury in that, a competent person did not perform an effective inspection of the excavation and adjacent areas for evidence of hazardous conditions.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 335998191.