Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: JDT CONSTRUCTION

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of JDT CONSTRUCTION in 236 WEST MARKET STREET, WEST CHESTER, PA 19382 (NAICS 238170). OSHA activity number 336092580.

Watch JDT Construction — free Get an email when a new federal OSHA severe-injury report for JDT Construction is published. One employer, no account, unsubscribe in one click.
Establishment
JDT CONSTRUCTION
Site address
236 WEST MARKET STREET
City
WEST CHESTER
State
PA
ZIP
19382
Mailing
10 NORTH BACTON HILL ROAD, MALVERN, PA 19355
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238170
Employees
4
Ownership type
A

4 citations on file for this inspection.

1926.451 G01 I

Serious Gravity 10 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $2100.00 · Current $2100.00
29 CFR 1926.451(g)(1)(i):     Each employee on a boatswains' chair, catenary scaffold, float scaffold, needle beam scaffold, or ladder jack scaffold shall be protected by a personal fall arrest system;    1. Jobsite, 236 West Market Street, Building Facade - Employees were conducting siding installation activities from a ladder jack scaffold 11' above ground level without a personal fall arrest system. Observed on or about August 29, 2012.
Recent events (1)
  • — Z (S) $2100

1926.454 A

Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.454(a):     The employer shall have each employee who performs work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards. The training shall include the following areas, as applicable:    1. Jobsite, 236 West Market Street, Building Facade - Employees were conducting siding installation activities from a ladder jack scaffold 11' above ground level without scaffold safety training. Observed on or about August 29, 2012.
Recent events (1)
  • — Z (S) $0

1926.451 F06

Serious Gravity 10 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $2100.00 · Current $2100.00
29 CFR 1926.451(f)(6):     The clearance between scaffolds and power lines shall be as follows: Scaffolds shall not be erected, used, dismantled, altered, or moved such that they or any conductive material handled on them might come closer to exposed and energized power lines than as follows:                        *Insulated Lines    _____________________________________________________________________                                                      Voltage          Minimum distance           Alternatives  ____________________ ________________________ _______________________                                                 Less than 300 volts.  3 feet (0.9 m)            300 volts to 50 kv.  10 feet (3.1 m)           More than 50 kv.....  10 feet (3.1 m) plus     2 times the length                        0.4 inches (1.0 cm)      of the line                        for each 1 kv over       insulator, but never                        50 kv.                   less than 10                                                 feet (3.1 m).  ____________________ ________________________ _______________________                            *Uninsulated lines  _____________________________________________________________________                                                     Voltage           Minimum distance         Alternatives  ____________________ ________________________ _______________________                                                 Less than 50 kv.....  10 feet (3.1 m).          More than 50 kv.....  10 feet (3.1 m) plus     2 times the length of                        0.4 inches (1.0 cm)      the line insulator,                        for each 1 kv over       but never less than                        50 kv.                   10 feet (3.1 m).  ____________________ ________________________ _______________________    Exception to paragraph (f)(6): Scaffolds and materials may be closer to power lines than specified above where such clearance is necessary for performance of work, and only after the utility company, or electrical system operator, has been notified of the need to work closer and the utility company, or electrical system operator, has deenergized the lines, relocated the lines, or installed protective coverings to prevent accidental contact with the lines.    1. Jobsite, 236 West Market Street, Building Facade, Electrical Drop Line - Employees were conducting siding installation operations from a ladder jack scaffold less then 1' from the building's 240v electrical service line. Observed on or about August 29, 2012.
Recent events (1)
  • — Z (S) $2100

1926.20 B01

Other-than-serious 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.20(b)(1):     It shall be the responsibility of the employer to initiate and maintain such programs as may be necessary to comply with this part.    1. Jobsite, 236 West Market Street - The employer did not create and/or maintain a written safety and health program where employees were conducting siding installation activities from a ladder jack scaffold without a personal fall arrest system or protection from electrical hazards. Observed on or about August 29, 2012.
Recent events (1)
  • — Z (O) $0

View JDT CONSTRUCTION's full OSHA safety record →