WEST CHESTER, PA —
OSHA Inspection: JDT CONSTRUCTION
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of JDT CONSTRUCTION in 236 WEST MARKET STREET, WEST CHESTER, PA 19382 (NAICS 238170). OSHA activity number 336092580.
Where did this inspection happen?
- Establishment
- JDT CONSTRUCTION
- Site address
- 236 WEST MARKET STREET
- City
- WEST CHESTER
- State
- PA
- ZIP
- 19382
- Mailing
- 10 NORTH BACTON HILL ROAD, MALVERN, PA 19355
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238170
- Employees
- 4
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.451 G01 I
- Issued
- Abate by
- Penalty
- Initial $2100.00 · Current $2100.00
General-duty citation text
29 CFR 1926.451(g)(1)(i): Each employee on a boatswains' chair, catenary scaffold, float scaffold, needle beam scaffold, or ladder jack scaffold shall be protected by a personal fall arrest system; 1. Jobsite, 236 West Market Street, Building Facade - Employees were conducting siding installation activities from a ladder jack scaffold 11' above ground level without a personal fall arrest system. Observed on or about August 29, 2012.
Recent events (1)
- — Z (S) $2100
1926.454 A
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.454(a): The employer shall have each employee who performs work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards. The training shall include the following areas, as applicable: 1. Jobsite, 236 West Market Street, Building Facade - Employees were conducting siding installation activities from a ladder jack scaffold 11' above ground level without scaffold safety training. Observed on or about August 29, 2012.
Recent events (1)
- — Z (S) $0
1926.451 F06
- Issued
- Abate by
- Penalty
- Initial $2100.00 · Current $2100.00
General-duty citation text
29 CFR 1926.451(f)(6): The clearance between scaffolds and power lines shall be as follows: Scaffolds shall not be erected, used, dismantled, altered, or moved such that they or any conductive material handled on them might come closer to exposed and energized power lines than as follows: *Insulated Lines _____________________________________________________________________ Voltage Minimum distance Alternatives ____________________ ________________________ _______________________ Less than 300 volts. 3 feet (0.9 m) 300 volts to 50 kv. 10 feet (3.1 m) More than 50 kv..... 10 feet (3.1 m) plus 2 times the length 0.4 inches (1.0 cm) of the line for each 1 kv over insulator, but never 50 kv. less than 10 feet (3.1 m). ____________________ ________________________ _______________________ *Uninsulated lines _____________________________________________________________________ Voltage Minimum distance Alternatives ____________________ ________________________ _______________________ Less than 50 kv..... 10 feet (3.1 m). More than 50 kv..... 10 feet (3.1 m) plus 2 times the length of 0.4 inches (1.0 cm) the line insulator, for each 1 kv over but never less than 50 kv. 10 feet (3.1 m). ____________________ ________________________ _______________________ Exception to paragraph (f)(6): Scaffolds and materials may be closer to power lines than specified above where such clearance is necessary for performance of work, and only after the utility company, or electrical system operator, has been notified of the need to work closer and the utility company, or electrical system operator, has deenergized the lines, relocated the lines, or installed protective coverings to prevent accidental contact with the lines. 1. Jobsite, 236 West Market Street, Building Facade, Electrical Drop Line - Employees were conducting siding installation operations from a ladder jack scaffold less then 1' from the building's 240v electrical service line. Observed on or about August 29, 2012.
Recent events (1)
- — Z (S) $2100
1926.20 B01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.20(b)(1): It shall be the responsibility of the employer to initiate and maintain such programs as may be necessary to comply with this part. 1. Jobsite, 236 West Market Street - The employer did not create and/or maintain a written safety and health program where employees were conducting siding installation activities from a ladder jack scaffold without a personal fall arrest system or protection from electrical hazards. Observed on or about August 29, 2012.
Recent events (1)
- — Z (O) $0
More inspections at JDT CONSTRUCTION
BROOKLYN, NY—2016-01-12 00:00:00
JDT CONSTRUCTION
View JDT CONSTRUCTION's full OSHA safety record →
More inspections in this industry (NAICS 238170)
OXFORD, OH—2026-07-13
R&R SIDING LLC
WINSTON SALEM, NC—2026-07-10
161522 - MS SIDING LLC
SLINGER, WI—2026-07-10
DYLAN MATTHEW SHELLEY LLC
WINSTON SALEM, NC—2026-07-09
161514 - ALPHA OMEGA CONSTRUCTION GROUP, INC
ATLANTA, GA—2026-07-09
ESV CONSTRUCTION LLC
More inspections in PA
MILTON, PA—2026-07-10
HOMETOWN FOODS CHEF BOYARDEE CO.
SUNBURY, PA—2026-07-10
DEMPSEY UNIFORM & LINEN SUPPLY, INC
LANDISVILLE, PA—2026-07-10
FAIRVIEW DEMOLITION LLC
YORK, PA—2026-07-10
AMERICAN SPECIALTY SYSTEMS INC.
WILLIAMSPORT, PA—2026-07-10
INTERNATIONAL PAINT PROS
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 336092580.