OSHA Inspection: K.J. CUSTOM CARPENTRY

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of K.J. CUSTOM CARPENTRY in 3 KALEIGH COURT, SOUTH BARRINGTON, IL 60010 (NAICS 238130). OSHA activity number 336118583.

Watch K.J. Custom Carpentry — free Get an email when a new federal OSHA severe-injury report for K.J. Custom Carpentry is published. One employer, no account, unsubscribe in one click.
Site address
3 KALEIGH COURT
City
SOUTH BARRINGTON
State
IL
ZIP
60010
Mailing
27625 N. OAK ST., ISLAND LAKE, IL 60042
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
5
Ownership type
A

8 citations on file for this inspection.

1926.304 I01

Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $2400.00 · Current $1350.00 Reduced
29 CFR 1926.304(i)(1): Each circular hand-fed ripsaw was not guarded by a hood completely enclosing the portion of the saw above the table and the portion of the saw above the material being cut:    a) The employer provided for employee use a Hitachi Model C10RB table saw without a blade guard.    No abatement certification or documentation required for this item.
Recent events (2)
  • — I (S) $1350
  • — Z (S) $2400

1926.404 B01 II

Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $1600.00 · Current $900.00 Reduced
29 CFR 1926.404(b)(1)(ii): All 120-volt, single-phase, 15 and 20 ampere receptacle outlets which were not a part of the permanent wiring of the building or structure and which were used by employees did not have approved ground-fault circuit interrupters for personnel protection (NOTE: Receptacles on a two-wire, single-phase portable or vehicle-mounted  generator not more than 5kW, where the circuit conductors of the generator are insulated from the generator frame and all other grounded surfaces, need not be protected with ground-fault circuit interrupters.):    a) Employees were using a Rigid Model RD80011 8000 watt gas powered generator to provide electric power at the site where the 120/240 volt 30 amp twist outlet was not equipped with ground-fault circuit interrupters.    No abatement certification or documentation required for this item.
Recent events (2)
  • — I (S) $900
  • — Z (S) $1600

1926.404 F06

Serious 1 instance 2 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous:    a) The employer provided for employee use at the job site a DeWalt 4.5 gallon portable electric air compressor Model D551446  that did not have a grounding pin.    No abatement certification or documentation required for this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.403 B02

Serious Gravity 5 2 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.403(b)(2):  Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification:    a) The employer provided for employee use a 10/4 30-amp adapter cord to plug into the 30-amp twist outlet on the Rigid 8000 watt portable generator that had a broken power-reset safety switch.     No abatement certification or documentation required for this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.451 C02 IV

Serious Gravity 10 1 instance 1 exposed
Issued
Penalty
Initial $2800.00 · Current $1550.00 Reduced
29 CFR 1926.451(c)(2)(iv): Front-end loaders and similar pieces of equipment used to support scaffold platforms were not specifically designed by the manufacturer for such use:    a) The employer provided a CareLift Zoom Boom Telehandler rough terrain forklift Model ZB6042-44 to elevate a wood platform for employee use and the manufacturer did not design the equipment for such use.    No abatement certification or documentation required for this item.
Recent events (2)
  • — I (S) $1550
  • — Z (S) $2800

1926.1051 A

Serious Gravity 10 1 instance 1 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.1051(a):  Stairways or ladders were not provided  at all personnel points of access where there was a break in elevation of 19 inches (48 cm) or more, and no ramp, runway, sloped embankment, or personnel hoist was provided:    a) An employee accessed a platform elevated by a CareLift Zoom Boom telehandler rough terrain forklift by going through a window opening on the third floor. The bottom of the window opening as approximately 37 inches above the floor and a stairway or ladder was not provided. The employee was exposed to a fall to the ground of approximately 26 feet.     No abatement certification or documentation required for this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.501 B13

Serious Gravity 5 2 instances 2 exposed
Issued
Penalty
Initial $2000.00 · Current $1100.00 Reduced
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet or more above the lower levels was not protected by a guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of 1926.502:    a) Employees were not protected from the unprotected side or edge on the walking working surface on the third floor and were exposed to a fall of approximately ten feet to the second floor.    b) Employees were exposed to falls up to approximately17 feet through window openings on the second floor which did not have top rails.    No abatement certification or documentation required for this item.
Recent events (2)
  • — I (S) $1100
  • — Z (S) $2000

1910.178 L04 III

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $1100.00 Reduced
29 CFR 1926.602(d) NOTE: The requirements applicable to construction work under this section are identical to those set forth at 29 CFR 1910.178(l) of this chapter.    29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator(s) performance was not conducted at least once every three years.    a) The employer did not ensure that the employee operating the CareLift Zoom Boom Telehandler rough terrain forklift Model ZB6042-44 was evaluated at least once every three years.    In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).