SOUTH BARRINGTON, IL —
OSHA Inspection: K.J. CUSTOM CARPENTRY
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of K.J. CUSTOM CARPENTRY in 3 KALEIGH COURT, SOUTH BARRINGTON, IL 60010 (NAICS 238130). OSHA activity number 336118583.
Where did this inspection happen?
- Establishment
- K.J. CUSTOM CARPENTRY
- Site address
- 3 KALEIGH COURT
- City
- SOUTH BARRINGTON
- State
- IL
- ZIP
- 60010
- Mailing
- 27625 N. OAK ST., ISLAND LAKE, IL 60042
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 5
- Ownership type
- A
Citations
8 citations on file for this inspection.
1926.304 I01
- Issued
- Penalty
- Initial $2400.00 · Current $1350.00 Reduced
General-duty citation text
29 CFR 1926.304(i)(1): Each circular hand-fed ripsaw was not guarded by a hood completely enclosing the portion of the saw above the table and the portion of the saw above the material being cut: a) The employer provided for employee use a Hitachi Model C10RB table saw without a blade guard. No abatement certification or documentation required for this item.
Recent events (2)
- — I (S) $1350
- — Z (S) $2400
1926.404 B01 II
- Issued
- Penalty
- Initial $1600.00 · Current $900.00 Reduced
General-duty citation text
29 CFR 1926.404(b)(1)(ii): All 120-volt, single-phase, 15 and 20 ampere receptacle outlets which were not a part of the permanent wiring of the building or structure and which were used by employees did not have approved ground-fault circuit interrupters for personnel protection (NOTE: Receptacles on a two-wire, single-phase portable or vehicle-mounted generator not more than 5kW, where the circuit conductors of the generator are insulated from the generator frame and all other grounded surfaces, need not be protected with ground-fault circuit interrupters.): a) Employees were using a Rigid Model RD80011 8000 watt gas powered generator to provide electric power at the site where the 120/240 volt 30 amp twist outlet was not equipped with ground-fault circuit interrupters. No abatement certification or documentation required for this item.
Recent events (2)
- — I (S) $900
- — Z (S) $1600
1926.404 F06
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous: a) The employer provided for employee use at the job site a DeWalt 4.5 gallon portable electric air compressor Model D551446 that did not have a grounding pin. No abatement certification or documentation required for this item.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.403 B02
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification: a) The employer provided for employee use a 10/4 30-amp adapter cord to plug into the 30-amp twist outlet on the Rigid 8000 watt portable generator that had a broken power-reset safety switch. No abatement certification or documentation required for this item.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 C02 IV
- Issued
- Penalty
- Initial $2800.00 · Current $1550.00 Reduced
General-duty citation text
29 CFR 1926.451(c)(2)(iv): Front-end loaders and similar pieces of equipment used to support scaffold platforms were not specifically designed by the manufacturer for such use: a) The employer provided a CareLift Zoom Boom Telehandler rough terrain forklift Model ZB6042-44 to elevate a wood platform for employee use and the manufacturer did not design the equipment for such use. No abatement certification or documentation required for this item.
Recent events (2)
- — I (S) $1550
- — Z (S) $2800
1926.1051 A
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.1051(a): Stairways or ladders were not provided at all personnel points of access where there was a break in elevation of 19 inches (48 cm) or more, and no ramp, runway, sloped embankment, or personnel hoist was provided: a) An employee accessed a platform elevated by a CareLift Zoom Boom telehandler rough terrain forklift by going through a window opening on the third floor. The bottom of the window opening as approximately 37 inches above the floor and a stairway or ladder was not provided. The employee was exposed to a fall to the ground of approximately 26 feet. No abatement certification or documentation required for this item.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.501 B13
- Issued
- Penalty
- Initial $2000.00 · Current $1100.00 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet or more above the lower levels was not protected by a guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of 1926.502: a) Employees were not protected from the unprotected side or edge on the walking working surface on the third floor and were exposed to a fall of approximately ten feet to the second floor. b) Employees were exposed to falls up to approximately17 feet through window openings on the second floor which did not have top rails. No abatement certification or documentation required for this item.
Recent events (2)
- — I (S) $1100
- — Z (S) $2000
1910.178 L04 III
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $1100.00 Reduced
General-duty citation text
29 CFR 1926.602(d) NOTE: The requirements applicable to construction work under this section are identical to those set forth at 29 CFR 1910.178(l) of this chapter. 29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator(s) performance was not conducted at least once every three years. a) The employer did not ensure that the employee operating the CareLift Zoom Boom Telehandler rough terrain forklift Model ZB6042-44 was evaluated at least once every three years. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- — I (S) $1100
- — Z (S) $2000
More inspections in this industry (NAICS 238130)
MOUNT JULIET, TN—2026-07-17 00:00:00
M AND F CONSTRUCTION LLC
MERIDIAN, ID—2026-07-17 00:00:00
CARRILLO CONSTRUCTION LLC
MERIDIAN, ID—2026-07-17 00:00:00
SEVY BROTHERS CONSTRUCTION LLC
WESTFORD, MA—2026-07-17 00:00:00
M&M CONSTRUCTION SERVICES CORP
FAIRHOPE, AL—2026-07-16 00:00:00
FRANCISCO ARIAS
More inspections in IL
FRANKFORT, IL—2026-07-17 00:00:00
QUANTUM TECHNICAL SERVICES INC.
ROCK ISLAND, IL—2026-07-17 00:00:00
AUGUSTANA COLLEGE
WASHINGTON, IL—2026-07-17 00:00:00
SUNRUN INSTALLATION SERVICES, INC.
FOREST PARK, IL—2026-07-17 00:00:00
CONSERVATION OF SCULPTURE & OBJECTS STUDIO, INC.
BLUE ISLAND, IL—2026-07-17 00:00:00
PROFLOW PUMPING SOLUTIONS
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 336118583.