SHERRILL, NY —
OSHA Inspection: JDLR ENTERPRISES, LLC DBA NOBLE WOOD SHAVINGS
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of JDLR ENTERPRISES, LLC DBA NOBLE WOOD SHAVINGS in 104 E. SENECA STREET, SHERRILL, NY 13461 (NAICS 321113). OSHA activity number 336120183.
Where did this inspection happen?
- Establishment
- JDLR ENTERPRISES, LLC DBA NOBLE WOOD SHAVINGS
- Site address
- 104 E. SENECA STREET
- City
- SHERRILL
- State
- NY
- ZIP
- 13461
- Mailing
- 7228 KLOCK ROAD, CANASTOTA, NY 13032
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 321113
- Employees
- 8
- Ownership type
- A
Citations
9 citations on file for this inspection.
1910.22 A01
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $1200.00 Reduced
General-duty citation text
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms or service rooms were not kept clean and orderly or in a sanitary condition: a) In the mill, on or about 9/19/12: There was an accumulation of wood dust throughout the mill. Abatement certification must be submitted for this item.
Recent events (2)
- — I (S) $1200
- — Z (S) $2000
1910.219 D01
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $2000.00
General-duty citation text
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): a) In the mill, on or about 9/19/12: Pulleys driving the drag chain for the surge bin were not guarded. Abatement certification must be submitted for this item.
Recent events (2)
- — I (S) $2000
- — Z (S) $2000
1910.219 E03 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.219(e)(3)(i): Vertical or inclined belt(s) were not enclosed by guard(s) conforming to the requirements specified at 29 CFR 1910.219(m) and (o): a) In the mill, on or about 9/19/12: V belt driving the drag chain for the surge bin was not guarded. Abatement certification must be submitted for this item.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.219 F03
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.219(f)(3): Sprocket wheels and chains which were seven -7 feet or less above floors or platforms were not enclosed: a) In the mill, shaving mill area, on or about 9/19/12: Ingoing nip points on the drag chain conveyor and sprocket at the discharge end were not guarded. Abatement certification must be submitted for this item.
Recent events (2)
- — I (S) $0
- — Z (S) $2000
1910.303 B07 IV
- Issued
- Abate by
- Penalty
- Initial $1200.00 · Current $720.00 Reduced
General-duty citation text
29 CFR 1910.303(b)(7)(iv): There were damaged parts that could adversely affect safe operation or mechanical strength of the equipment, such as parts that were broken, bent, cut, or deteriorated by corrosion, chemical action, or overheating: a) In the mill, on or about 9/19/12: Flexible conduit providing current to the shaver was crushed and damaged. Abatement certification must be submitted for this item.
Recent events (2)
- — I (S) $720
- — Z (S) $1200
1910.305 B01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.305(b)(1): Openings through which conductors enter boxes, cabinets, or fittings were not effectively closed: a) In the mill, bagger area, on or about 9/19/12: Flexible cord was pulled loose from fitting on a circuit breaker box for the bagger equipment, located on the column, was not effectively closed. Abatement certification must be submitted for this item.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 B01 II
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in cabinets, boxes, and fittings shall be effectively closed: a) In the mill, bagging area, on or about 9/19/12: Knockout was missing on a 440 outlet on the column near the bagger. Abatement certification must be submitted for this item.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.141 D02 II
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.141(d)(2)(ii): Lavatories were not provided with hot and cold, or tepid running water: a) At the establishment, on or about 9/19/12: The lavatory was not provided with hot or tepid running water. Abatement certification must be submitted for this item.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.1200 E01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: a) At the establishment, on or about 9/19/12: There was no written hazard communication program for employees using and/or exposed to various products, including, but not limited to wood dust, propane, hydraulic oil, gear oil, antifreeze, etc. Abatement certification must be submitted for this item.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 321113)
COCHRANTON, PA—2026-07-15 00:00:00
CRAWFORD COUNTY HARDWOODS, LLC
COCHRANTON, PA—2026-07-15 00:00:00
CRAWFORD COUNTY HARDWOODS, LLC
LIVE OAK, FL—2026-07-09 00:00:00
BINDERHOLZ LIVE OAK LLC
LAFAYETTE, TN—2026-07-08 00:00:00
CLARK LUMBER COMPANY, LLC
GASTON, OR—2026-07-07 00:00:00
317744699 - STIMSON LUMBER COMPANY
More inspections in NY
LIBERTY, NY—2026-07-17 00:00:00
SULLIVAN COUNTY CARE CENTER AT SUNSET LAKE
NEW YORK, NY—2026-07-17 00:00:00
VERGARA ELECTRICAL LLC
ONEONTA, NY—2026-07-17 00:00:00
APPLE CONVERTING, INC.
SYRACUSE, NY—2026-07-17 00:00:00
NAMICELA HOME SOLUTIONS INC
SYRACUSE, NY—2026-07-17 00:00:00
CRANESVILLE BLOCK CO., INC.
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 336120183.