Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: WOODS & BRUCE ELECTRIC COMPANY

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of WOODS & BRUCE ELECTRIC COMPANY in 1206 N. BELT HIGHWAY, SAINT JOSEPH, MO 64503 (NAICS 238210). OSHA activity number 336223789.

Watch Woods & Bruce Electric Company — free Get an email when a new federal OSHA severe-injury report for Woods & Bruce Electric Company is published. One employer, no account, unsubscribe in one click.
Site address
1206 N. BELT HIGHWAY
City
SAINT JOSEPH
State
MO
ZIP
64503
Mailing
#2 SUMMERHILL DRIVE, SAINT JOSEPH, MO 64507
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238210
Employees
3
Ownership type
A

2 citations on file for this inspection.

1926.403 B01

Deleted Serious Gravity 5 1 instance 3 exposed
Issued
Penalty
Initial $1440.00 · Current $0.00 Reduced
29 CFR 1926.403(b)(1):     Examination. The employer shall ensure that electrical equipment is free from recognized hazards that are likely to cause death or serious physical harm to employees. Safety of equipment shall be determined on the basis of the following considerations:    (a).  Worksite located at 1206 N. Belt Highway, St. Joseph, Missouri- Employees were exposed to a shock or electrocution hazard in that the cord  being used to power a junction box had serveral places were the outer insulation had been breached.
Recent events (2)
  • — I (S) $0
  • — Z (S) $1440

1926.404 B01 III D 2

Deleted Serious Gravity 5 1 instance 3 exposed
Issued
Penalty
Initial $2160.00 · Current $0.00 Reduced
29 CFR 1926.404(b)(1)(iii)(D)(2):     Each receptacle and attachment cap or plug shall be tested for correct attachment of the equipment grounding conductor. The equipment grounding conductor shall be connected to its proper terminal.    (a).  Worksite locateda at 1206 N. Belt Highway, St. Joseph, Missouri- Employees were exposed to a shock or electrocution hazard in that the outlet being used to power equipment had not been tested to siee if it was properly grounded. The junction box was also not of an insulative material and an electrical charge could be felt on the exterior of the box.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2160