PHILADELPHIA, PA —
OSHA Inspection: P. MARCO
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of P. MARCO in 321 N. 19TH ST., PHILADELPHIA, PA 19103 (NAICS 238140). OSHA activity number 336430384.
Where did this inspection happen?
- Establishment
- P. MARCO
- Site address
- 321 N. 19TH ST.
- City
- PHILADELPHIA
- State
- PA
- ZIP
- 19103
- Mailing
- 1460 GLEN ECHO DR., HUNTINGDON VALLEY, PA 19006
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 1
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.451 B01
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $2800.00
General-duty citation text
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii) a) Jobsite: 321 N. 19th St., Philadelphia - Employees working on a fabricated frame scaffold were exposed to fall hazards of approximately 26 feet. Each platform on all working levels of the fabricated frame scaffold were not fully planked as required by this section. Observed on or about 09/14/12.
Recent events (1)
- — Z (S) $2800
1926.451 F03
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.451(f)(3): Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity: a) Jobsite: 321 N. 19th St., Philadelphia - Fabricated frame scaffolds and scaffold components were not inspected for visible defects, such as lack of guardrail systems by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity. Observed on or about 09/14/12.
Recent events (1)
- — Z (S) $0
1926.451 G01 VII
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $2800.00
General-duty citation text
29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section. a) Jobsite: 321 N. 19th St., Philadelphia - Each employee performing stucco operations from a fabricated frame scaffold approximately 26 feet above ground level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section. Observed on or about 09/14/12.
Recent events (1)
- — Z (S) $2800
1926.454 A
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards. a) Jobsite: 321 N. 19th St., Philadelphia - The employer did not have each employee performing stucco operations from a fabricated frame scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards. Observed on or about 09/14/12.
Recent events (1)
- — Z (S) $0
1926.451 E01
- Issued
- Abate by
- Penalty
- Initial $1600.00 · Current $1600.00
General-duty citation text
29 CFR 1926.451(e)(1): A means of access for scaffold platforms more than 2 feet (0.6 m) above or below a point of access, such as portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface was not used. a) Jobsite: 321 N. 19th St., Philadelphia - Employees were observed using the frames of a fabricated frame scaffold to climb up and down from a working platform of the scaffold. The working platform was approximately 26 feet above ground level. Observed on or about 09/14/12.
Recent events (1)
- — Z (S) $1600
More inspections in this industry (NAICS 238140)
RENO, NV—2026-07-16 00:00:00
DC MASONRY
WINNETKA, IL—2026-07-15 00:00:00
CHICAGO STUCCO CO.
LODI, NJ—2026-07-15 00:00:00
J & O MASONRY CONTRACTORS
DORAVILLE, GA—2026-07-14 00:00:00
SUDLOW CONCRETE, INC.
FLAGLER BEACH, FL—2026-07-14 00:00:00
PLANET DESIGN SERVICES, INC.
More inspections in PA
PHILADELPHIA, PA—2026-07-16 00:00:00
URUS CONSTRUCTION CORPORATION
JEFFERSON HILLS, PA—2026-07-16 00:00:00
MARATHON PETROLEUM COMPANY ASPHALT TERMINAL
SMITHFIELD, PA—2026-07-16 00:00:00
CARLISLE CONSTRUCTION MATERIALS
PITTSBURGH, PA—2026-07-15 00:00:00
DREAM GREENER LAWN & LANDSCAPE
COCHRANTON, PA—2026-07-15 00:00:00
CRAWFORD COUNTY HARDWOODS, LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 336430384.