WASHINGTON, DC —
OSHA Inspection: JULIO ARGUETA CONSTRUCTION
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of JULIO ARGUETA CONSTRUCTION in 1437 IRVING ST. NE, WASHINGTON, DC 20017 (NAICS 531210). OSHA activity number 336559380.
Where did this inspection happen?
- Establishment
- JULIO ARGUETA CONSTRUCTION
- Site address
- 1437 IRVING ST. NE
- City
- WASHINGTON
- State
- DC
- ZIP
- 20017
- Mailing
- 7554 KINGMAN DR., ANNANDALE, VA 22003
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 531210
- Employees
- 5
- Ownership type
- A
Citations
6 citations on file for this inspection.
1926.405 B02
- Issued
- Abate by
- Penalty
- Initial $1600.00 · Current $1600.00
General-duty citation text
29 CFR 1926.405(b)(2): In energized installations each outlet box did not have a cover, faceplate, or fixture canopy. a) Employees were observed using a 15 ampere outlet without a cover exposing them to electrical hazards.
Recent events (1)
- — Z (S) $1600
1926.404 B01 II
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.404(b)(1)(ii): All 120-volt, single-phase 15- and 20-ampere receptacle outlets on construction sites, which are not a part of the permanent wiring of the building or structure and which are in use by employees, did not have approved ground-fault circuit interrupters for personnel protection. a) Employees were observed using a 15 ampere outlet without ground fault circuit interruption protection exposing them to electrical hazards. The outlet was powering an air compressor and other tools and was not covered.
Recent events (1)
- — Z (S) $0
1926.451 G01
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $2800.00
General-duty citation text
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet (3.1 m) above a lower level was not protected from falling to that lower level. a) Employees were observed on a pump jack scaffold 18 feet in height without fall protection exposed to a fall hazard. Abatement Documentation Required
Recent events (1)
- — Z (S) $2800
1926.452 J02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.452(j)(2): Poles were not secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary. a) Employees were observed on a pump jack scaffold 18 feet in height with no bracing at the bottom of the poles exposed to a fall hazard from an unstable scaffold. Abatement Documentation Required
Recent events (1)
- — Z (S) $0
1926.451 B03
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.451(b)(3): The front edge of all platforms were more than 14 inches (36 cm) from the face of the work, unless guardrail systems are erected along the front edge and/or personal fall arrest systems are used in accordance with paragraph (g) of this section to protect employees from falling. a) Employees were observed on a pump jack scaffold 18 1/2 inches away from the face of the wall exposed to a fall hazard. Abatement Documentation Required
Recent events (1)
- — Z (S) $0
1926.1052 C01
- Issued
- Abate by
- Penalty
- Initial $1600.00 · Current $1600.00
General-duty citation text
29 CFR 1926.1052(c)(1): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with a stair rail and/or a handrail: a) Employees were observed using a set of stairs 15 risers in height with no hand and/or stair rail.
Recent events (1)
- — Z (S) $1600
More inspections in this industry (NAICS 531210)
JACKSONVILLE, FL—2026-06-24 00:00:00
PARADISE BUILDERS OF NORTH FLORIDA LLC
SEATTLE, WA—2026-06-08 00:00:00
WA317991568 - TANG REAL ESTATE INVESTMENTS CORP
CORONA, NY—2026-05-13 00:00:00
THE RELATED COMPANIES, LP
SEATTLE, WA—2026-05-08 00:00:00
WA317991153 - TANG REAL ESTATE INVESTMENTS CORP
BRADLEY, IL—2026-04-28 00:00:00
GOOD LYFE PROPERTIES LLC
More inspections in DC
WASHINGTON, DC—2026-06-30 00:00:00
U.S. DEPARTMENT OF AGRICULTURE