BUFFALO, NY —
OSHA Inspection: METAL PREPARATIONS PRODUCTS
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of METAL PREPARATIONS PRODUCTS in 752 MILITARY ROAD, BUFFALO, NY 14216 (NAICS 811310). OSHA activity number 336650189.
Where did this inspection happen?
- Establishment
- METAL PREPARATIONS PRODUCTS
- Site address
- 752 MILITARY ROAD
- City
- BUFFALO
- State
- NY
- ZIP
- 14216
- Mailing
- 752 MILITARY ROAD, BUFFALO, NY 14216
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 811310
- Employees
- 35
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.37 B02
- Issued
- Abate by
- Penalty
- Initial $1890.00 · Current $945.00 Reduced
General-duty citation text
29 CFR 1910.37(b)(2): Each exit must be clearly visible and marked by a sign reading "Exit." a) On or about 10/03/12 in the Grinding area; three doorways are located on the north side of this area. One of the doorways lead to the exit from the building and was not marked as an exit. Abatement Certification
Recent events (2)
- — I (S) $945
- — Z (S) $1890
1910.37 B05
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.37(b)(5): Each doorway or passage along an exit access that could be mistaken for an exit was not marked "Not an Exit" or similar designation, or be identified by a sign indicating its actual use (e.g. closet): a) On or about 10/03/12 in the Grinding area; the door leading to the old shower room located on the north side was not marked and could be mistaken for an exit. Abatement Certification
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.212 A01
- Issued
- Abate by
- Penalty
- Initial $2520.00 · Current $1260.00 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): Machine guarding was not provided to protect operator(s) and other employees from hazard(s) created by contacting the rotating grinding wheel on the edger machines: a) On or about 10/3/12 in the Grinder area; employees are inserting and removing scissor blades from the Edger machine at a distance of approximately two inches away from an unguarded ( 24" diameter ) grinding wheel exposing them to contact with the rotating wheel operating at a speed of 1745 rpms. Abatement Certification
Recent events (2)
- — I (S) $1260
- — Z (S) $2520
1910.303 B02
- Issued
- Abate by
- Penalty
- Initial $2520.00 · Current $1260.00 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: (a) On or about 10/3/12 in the Grinding room; a relocateable power tap was being to supply power to the Baldor grinder and sump pump exposing employee to contact with electric current. b) On or about 10/3/12 in the Grinding room; a relocateable power tap was plugged into a cord set which was plugged into a wall outlet exposing employee to contact with electric current. c) On or about 10/3/12 in the Grinding room; a Westinghouse brand motor starter ( #B100-3, Size M-1, Cat# BTOCM1CX ) is being used on an almost daily basis as a switch to turn on and turn off the hollow grinding machine. Abatement Certification
Recent events (2)
- — I (S) $1260
- — Z (S) $2520
1910.305 G01 IV A
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and cables were used as a substitute for the fixed wiring of a structure. a) On or about 10/3/12 in the Grinding area; a cord set was being used to supply power to a relocatable power tap that was being used to supply power to the table top grinder and sump pump. Abatement Certification
Recent events (2)
- — I (S) $0
- — Z (S) $0
1904.29 B03
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1904.29(b)(3): Each recordable injury or illness was not entered on the OSHA 300 Log and/or an incident report (OSHA Form 301 or equivalent) within seven (7) days of receiving information that a recordable injury or illness has occurred: a) On or about 10/3/12 throughout the facility; illness (dermatitis ) reported on 7/23/12 was not enterd on the OSHA 300 form. b) On or about 10/3/12 throughout the facility; injury occurring on 9/17/12 requiring sutures was not entered on the OSHA 300 form. Abatement Certification
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 811310)
PATERSON, NJ—2026-07-09 00:00:00
YHONNY REFRIGERATION
CHRISTIANSBURG, VA—2026-07-09 00:00:00
BGIS GLOBAL INTEGRATED SOLUTION US, LLC
SEATTLE, WA—2026-07-09 00:00:00
WA317992010 - FLAGSHIP MANAGEMENT LLC
STATESBORO, GA—2026-07-08 00:00:00
TAYLOR BUILT PRODUCTS
ANCHORAGE, AK—2026-07-08 00:00:00
ANGUS ENTERPRISES
More inspections in NY
LIBERTY, NY—2026-07-17 00:00:00
SULLIVAN COUNTY CARE CENTER AT SUNSET LAKE
NEW YORK, NY—2026-07-17 00:00:00