SHEBOYGAN, WI —
OSHA Inspection: KOENIG MACHINE INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of KOENIG MACHINE INC. in 5531 PLAYBIRD ROAD, SHEBOYGAN, WI 53083 (NAICS 333999). OSHA activity number 336688593.
Where did this inspection happen?
- Establishment
- KOENIG MACHINE INC.
- Site address
- 5531 PLAYBIRD ROAD
- City
- SHEBOYGAN
- State
- WI
- ZIP
- 53083
- Mailing
- 5531 PLAYBIRD ROAD, SHEBOYGAN, WI 53083
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 333999
- Employees
- 13
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.147 C01
- Issued
- Abate by
- Penalty
- Initial $1600.00 · Current $1120.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative: a) On or about October 4, 2012 the employer had not developed an energy control program to ensure that potentially hazardous energy sources were de-energized before employees performed cleaning operations inside equipment. Abatement Certification and Abatement Documentation Required.
Recent events (2)
- — I (S) $1120
- — Z (S) $1600
1910.178 L01 I
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $1400.00 Reduced
General-duty citation text
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator was competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l): a) On or about October 4, 2012 the employer did not require that each forklift operator had completed training and an evaluation to ensure safe forklift operations. Abatement Certification and Abatement Documentation Required.
Recent events (2)
- — I (S) $1400
- — Z (S) $2000
1910.212 A03 II
- Issued
- Abate by
- Penalty
- Initial $1600.00 · Current $1120.00 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(ii): Point of operation guards were not designed and constructed as to prevent the operator from having any part of their body in the danger zone during the operating cycle: a) On or about October 4, 2012 the interlock doors on the Viper VMC-1270 CNC machine was not installed properly. Operators were able to run the CNC without the doors being closed. b) On or about October 4, 2012 the interlock doors on the Viper VMC-2100 CNC machine was not installed properly. Operators were able to run the CNC without the doors being closed. Abatement Certification and Abatement Documentation Required.
Recent events (2)
- — I (S) $1120
- — Z (S) $1600
1910.132 D02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.132(d)(2): The employer did not verify that the required workplace hazard assessment has been performed through a written certification which included the requirements as outlined in 29 CFR 1910.132(d)(2): a) On or about October 4, 2012 the employer did not certify in writing that a hazard assessment for the appropriate personal protective equipment had been conducted. Abatement Certification and Abatement Documentation Required.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.134 C02 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.134(c)(2)(i): Respirator users were not provided with the information contained in Appendix D to 29 CFR 1910.134 when the employer determined that any voluntary respirator use was permissible: a) Employees provided with dust masks for voluntary use were not provided with the mandatory Appendix D of the respirator standard. Abatement Certification and Abatement Documentation Required.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.303 G01 II
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage: a) On or about October 4, 2012 the working space around Panel A, Panel AA, Panel B and various electrical disconnects along the east wall near the CNC machines was used for the storage of excess parts. There was not three (3) feet of clearance maintained around the electrical enclosures. No Abatement Certification or Abatement Documentation Required.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 333999)
RED LION, PA—2026-07-14 00:00:00
LION TOOL & DESIGN
YAUCO, PR—2026-06-24 00:00:00
SARTORIUS STEDIM FILTERS INC
PLYMOUTH, MI—2026-06-17 00:00:00
SKYWAY PRECISION INC
LEXINGTON, TN—2026-06-17 00:00:00
AUTOMATED MACHINE SPECIALTIES, INC.
ELBERTA, UT—2026-06-17 00:00:00
TAVACI TECHNOLOGIES
More inspections in WI
WAUSAU, WI—2026-07-16 00:00:00
MIRON CONSTRUCTION CO. INC.
ELROY, WI—2026-07-15 00:00:00
WABASH NATIONAL SERVICES, L.P.
SUSSEX, WI—2026-07-15 00:00:00
KINGS SUPERIOR CONSTRUCTION LLC
DELAVAN, WI—2026-07-15 00:00:00
TERONOMY BUILDERS, INC.
DELAVAN, WI—2026-07-15 00:00:00
A. GOMEZ CARPENTRY, INC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 336688593.