Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,645Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: KOENIG MACHINE INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of KOENIG MACHINE INC. in 5531 PLAYBIRD ROAD, SHEBOYGAN, WI 53083 (NAICS 333999). OSHA activity number 336688593.

Watch Koenig Machine INC. — free Get an email when a new federal OSHA severe-injury report for Koenig Machine INC. is published. One employer, no account, unsubscribe in one click.
Establishment
KOENIG MACHINE INC.
Site address
5531 PLAYBIRD ROAD
City
SHEBOYGAN
State
WI
ZIP
53083
Mailing
5531 PLAYBIRD ROAD, SHEBOYGAN, WI 53083
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333999
Employees
13
Ownership type
A

6 citations on file for this inspection.

1910.147 C01

Serious Gravity 5 1 instance 13 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $1120.00 Reduced
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative:    a) On or about October 4, 2012 the employer had not developed an energy control program to ensure that potentially hazardous energy sources were de-energized before employees performed cleaning operations inside equipment.     Abatement Certification and Abatement Documentation Required.
Recent events (2)
  • — I (S) $1120
  • — Z (S) $1600

1910.178 L01 I

Serious Gravity 5 4 instances 13 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $1400.00 Reduced
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator was competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l):    a) On or about October 4, 2012 the employer did not require that each forklift operator had completed training and an evaluation to ensure safe forklift operations.      Abatement Certification and Abatement Documentation Required.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2000

1910.212 A03 II

Serious Gravity 5 2 instances 2 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $1120.00 Reduced
29 CFR 1910.212(a)(3)(ii): Point of operation guards were not designed and constructed as to prevent the operator from having any part of their body in the danger zone during the operating cycle:    a) On or about October 4, 2012 the interlock doors on the Viper VMC-1270 CNC machine was not installed properly.  Operators were able to run the CNC without the doors being closed.     b) On or about October 4, 2012 the interlock doors on the Viper VMC-2100 CNC machine was not installed properly.  Operators were able to run the CNC without the doors being closed.     Abatement Certification and Abatement Documentation Required.
Recent events (2)
  • — I (S) $1120
  • — Z (S) $1600

1910.132 D02

Other-than-serious 1 instance 13 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.132(d)(2): The employer did not verify that the required workplace hazard assessment has been performed through a written certification which included the requirements as outlined in 29 CFR 1910.132(d)(2):    a) On or about October 4, 2012 the employer did not certify in writing that a hazard assessment for the appropriate personal protective equipment had been conducted.     Abatement Certification and Abatement Documentation Required.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.134 C02 I

Other-than-serious 1 instance 13 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.134(c)(2)(i): Respirator users were not provided with the information contained in Appendix D to 29 CFR 1910.134 when the employer determined that any voluntary respirator use was permissible:    a) Employees provided with dust masks for voluntary use were not provided with the mandatory Appendix D of the respirator standard.      Abatement Certification and Abatement Documentation Required.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.303 G01 II

Other-than-serious 1 instance 13 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage:    a) On or about October 4, 2012 the working space around Panel A, Panel AA, Panel B and various electrical disconnects along the east wall near the CNC machines was used for the storage of excess parts. There was not three (3) feet of clearance maintained around the electrical enclosures.     No Abatement Certification or Abatement Documentation Required.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 336688593.