TUPELO, MS —
OSHA Inspection: JESCO MAINTENANCE CORPORATION
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of JESCO MAINTENANCE CORPORATION in 1804 S. GREEN ST., TUPELO, MS 38804 (NAICS 811310). OSHA activity number 336740782.
Where did this inspection happen?
- Establishment
- JESCO MAINTENANCE CORPORATION
- Site address
- 1804 S. GREEN ST.
- City
- TUPELO
- State
- MS
- ZIP
- 38804
- Mailing
- 2020 MCCULLOUGH BLVD, TUPELO, MS 38802
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 811310
- Employees
- 230
- Ownership type
- A
Citations
2 citations on file for this inspection.
5(a)(1)
- Issued
- Penalty
- Initial $2601.00 · Current $0.00 Reduced
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to burns. a. Z-Cal, Hydro-Therm On or about October 3, 2012 39 inches of insulation was missing from the lower section a steam pipe for the Hydro-Therm, Z-Cal.
Recent events (2)
- — I (S) $0
- — Z (S) $2601
1910.303 B07 I
- Issued
- Penalty
- Initial $1951.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.303(b)(7)(i): Unused openings in boxes, raceways, auxiliary gutters, cabinets, equipment cases, or housings shall be effectively closed to afford protection substantially equivalent to the wall of the equipment. a. #2 Comp Line - On or about October 3, 2012 The following electrical cabinets had openings in their covers: 1. (Un-used opening) the disconnect/reset lever was removed from electrical cabinet #T429 for the 2.5 inch extruder. 2. (Not completely closed) screws were missing from the digital monitor located in the center of electrical cabinet #T408. Approximately one-half inch gap was between the top of the monitor and cabinet cover.
Recent events (2)
- — I (S) $0
- — Z (S) $1951
More inspections at JESCO MAINTENANCE CORPORATION
TUPELO, MS—2017-05-11 00:00:00
JESCO MAINTENANCE CORPORATION
TUPELO, MS—2010-12-07 00:00:00
JESCO MAINTENANCE CORPORATION
View JESCO MAINTENANCE CORPORATION's full OSHA safety record →
More inspections in this industry (NAICS 811310)
CHRISTIANSBURG, VA—2026-07-09
BGIS GLOBAL INTEGRATED SOLUTION US, LLC
SEATTLE, WA—2026-07-09
WA317992010 - FLAGSHIP MANAGEMENT LLC
STATESBORO, GA—2026-07-08
TAYLOR BUILT PRODUCTS
, AK—2026-07-08
ANGUS ENTERPRISES
LOS ANGELES, CA—2026-07-08
CHILLEST INDUSTRIES LLC
More inspections in MS
LAUREL, MS—2026-07-01
THERMO-KOOL
HORN LAKE, MS—2026-07-01
NEWLY WEDS FOODS, INC.
GAUTIER, MS—2026-07-01
DOUBLE R GAUTIER, LLC
OLIVE BRANCH, MS—2026-06-30
HYVE SOLUTIONS
GAUTIER, MS—2026-06-30
STEVE WILSON ENTERPRISE
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 336740782.