Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,645Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: OLIVEIRA BROTHERS CONSTRUCTION CORP.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of OLIVEIRA BROTHERS CONSTRUCTION CORP. in COOPERS PLAZA 79 ROUTE 73, VOORHEES, NJ 08043 (NAICS 238140). OSHA activity number 336780192.

Watch Oliveira Brothers Construction Corp. — free Get an email when a new federal OSHA severe-injury report for Oliveira Brothers Construction Corp. is published. One employer, no account, unsubscribe in one click.
Site address
COOPERS PLAZA 79 ROUTE 73
City
VOORHEES
State
NJ
ZIP
08043
Mailing
110 JABEZ STREET SUITE 158, NEWARK, NJ 07105
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
6
Ownership type
A

7 citations on file for this inspection.

1926.100 A

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $2000.00 · Current $2000.00
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets:    (a) Cooper Plaza, Route 73 S. Voorhees, NJ: An employee working on the 2nd level of the scaffold was not wearing a hard hat while block laying and erection activities occurred, observed on or about 10/10/12.
Recent events (1)
  • — Z (S) $2000

1926.451 E01

Serious Gravity 10 1 instance 6 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $2800.00
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, sturcure, personnel hoist, or similar surface was not used.  Crossbraces were used as a means of access.    (a) Cooper Plaza, Route 73 S. Voorhees, NJ, North Side of Structure: Employees were accessing the top platform from the side bracket, (34 inches) by climbing the cross braces and end frames, observed on or about 10/10/12.    (b) Cooper Plaza, Route 73 S. Voorhees, NJ, North Side of Structure: A ladder was not provided for employees to use to access the third level of the scaffold , observed on or about 10/10/12.    NOTE:  IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (1)
  • — Z (S) $2800

1926.451 G01

Serious Gravity 10 1 instance 6 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $2800.00
29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section:    (a) Cooper Plaza, Route 73 S. Voorhees, NJ, North Side of Structure: Employees working on the 3rd level of the scaffold system, approximately 22 feet 10 inches above ground were not protected from falling, observed on or about 10/10/12.    NOTE:  IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (1)
  • — Z (S) $2800

1926.451 G04 XV

Serious Gravity 5 1 instance 6 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.451(g)(4)(xv): Crossbracing used in place of a midrail was unacceptable because the crossing point of two braces is between 20 inches (0.5 m) and 30 inches ((0.8 M) above the work platform or as a toprail when the crossing point of two braces is between 38 inches (0.97 m) and 48 inches (1.3 m) above the work platform.  The endpoints at each upright were more than 48 inches (1.3 m) apart.    (a) Cooper Plaza, Route 73 S. Voorhees, NJ, North Side of Structure: Cross bracing used on the scaffold was at an acceptable height to be used as a midrail; however there was no top rail , observed on or about 10/10/12.    NOTE:  THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM, FAILURE TO DO SO WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 AS PER 29 CFR 1903.19.
Recent events (1)
  • — Z (S) $0

1926.451 H02 II

Serious Gravity 5 1 instance 6 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $2000.00
29 CFR 1926.451(h)(2)(ii): A toeboard was not erected along the edge of platforms more than 10 feet (3.1 m) above lower levels for a distance sufficient to protect employees below:    (a) Cooper Plaza, Route 73 S. Voorhees, NJ: The scaffold system upon which employees were working on and around the base of were not provided with toeboards, observed on or about 10/10/12.    NOTE:  THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM, FAILURE TO DO SO WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 AS PER 29 CFR 1903.19.
Recent events (1)
  • — Z (S) $2000

1926.1053 B01

Serious Gravity 10 1 instance 6 exposed
Issued
Penalty
Initial $2800.00 · Current $2800.00
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladders length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:    (a) Cooper Plaza, Route 73 S. Voorhees, NJ, North Side of Structure: The Louisville yellow extension ladder model FE1728, was not extended to 3 feet beyond the access point, observed on or about 10/10/12.    NOTE:  IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (1)
  • — Z (S) $2800

1926.1053 B05 I

Serious Gravity 5 1 instance 6 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.1053(b)(5)(i): Non-self-supporting ladders were not used at an angle such than the horizontal distance from the top support to the foot of the ladder way approximately one-quarter of the working length of the ladder (the distance along the ladder between the foot and the top support.      (a) Cooper Plaza, Route 73 S. Voorhees, NJ, North Side of Structure: The Louisville yellow extension ladder model FE1728, was not placed at the proper angle, observed on or about 10/10/12.    NOTE:  IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (1)
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 336780192.