Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: HORIZON GROUP MANAGEMENT, LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of HORIZON GROUP MANAGEMENT, LLC in 5050 N. SHERIDAN RD., CHICAGO, IL 60640 (NAICS 236118). OSHA activity number 336918180.

Watch Horizon Group Management, LLC — free Get an email when a new federal OSHA severe-injury report for Horizon Group Management, LLC is published. One employer, no account, unsubscribe in one click.
Site address
5050 N. SHERIDAN RD.
City
CHICAGO
State
IL
ZIP
60640
Mailing
1946 W. LAWRENCE AVE., CHICAGO, IL 60640
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236118
Employees
80
Ownership type
A

11 citations on file for this inspection.

5(a)(1)

Serious Gravity 10 3 instances 1 exposed
Issued
Abate by
Penalty
Initial $4900.00 · Current $2362.00 Reduced
OSH ACT of 1970 Section (5)(a)(1):  Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing for likely to cause death or serious physical harm to employees in that employees were exposed to caught between and struck by hazard while operating the freight elevator:    a)  On or about October 17, 2012, employees were operating a freight elevator which was not equipped with an interior car gate, exposing employees to the hazard of amputation.     Among others, feasible and acceptable method of abatement would be to follow ASME A17.1-2010 - Safety code for Elevators and Escalators, Paragraph 2.14.1.1, and equip the elevator with an interior car gate.      b)  On or about October 17, 2012, employees were operating a freight elevator which was not equipped with a top car enclosure, exposing employees to struck-by hazards caused by the materials falling from upper floors.      Among others, feasible and acceptable method of abatement would be to follow ASME A17.1-2010 - Safety code for Elevators and Escalators, Paragraph 2.14.1.6.1, and equip the elevator with a top car enclosure.    c)  On or about October 17, 2012, employees were operating a freight elevator which was not equipped with an emergency stop switch in order to stop the elevator in case of emergency.      Among others, feasible and acceptable method of abatement would be to follow ASME A17.1-2010 - Safety code for Elevators and Escalators, Paragraph 2.26.2.5, and equip the elevator with a red in color, conspicuously and permanently marked emergency stop switch.       In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $2362
  • — Z (S) $4900

1926.20 B02

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $3500.00 · Current $1690.00 Reduced
29 CFR 1926.20(b)(2): The employer did not initiate and maintain programs which provided for frequent and regular inspections of the job site, materials and equipment to be made by a competent person(s):    a)  On or about October 17, 2012, the employer did not assign a competent person to conduct onsite inspections where employees were exposed to the hazards associated with the building renovation.       No abatement certification or documentation is required for this item.
Recent events (2)
  • — I (S) $1690
  • — Z (S) $3500

1926.21 B02

Serious Gravity 5 1 instance 3 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.21(b)(2): The employer did not instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his/her environment to control or eliminate any hazards or other exposure to illness or injury:     a) On or about October 17, 2012, the employer did not instruct or provide instruction to employees in the recognition and avoidance of unsafe conditions and the regulations applicable to their work environment to control or minimize the hazards associated with their work.     No abatement certification or documentation is required for this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.153 J

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $1355.00 Reduced
29 CFR 1926.153(j): Container(s) of liquefied petroleum gas (LP-Gas) were stored within building(s):    a)  On or about October 17, 2012, employees were storing containers of the liquefied petroleum gas (LP-Gas) on the 11th floor of the multifamily apartment building.      In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (S) $1355
  • — Z (S) $2800

1926.405 G01 III C

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $3500.00 · Current $1695.00 Reduced
29 CFR 1926.405(g)(1)(iii)(C): Flexible cords and cables were run through doorways, windows or similar openings:     a) On or about October 17, 2012, an extension cord was run through the storage room doorway on the first floor to power tools onsite.      In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (S) $1695
  • — Z (S) $3500

1926.404 F06

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.404(f)(6):  The path to ground from circuits, equipment, or enclosures was not permanent and continuous:    a)  On or about October 17, 2012, extension cords, used by employees onsite, did not have permanent and continuous path to ground.    In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.416 E02

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.416(e)(2):  Extension cords were fastened with staples, hung from nails, or suspended by wire:    a)  On or about October 17, 2012, extension cords, used by employees to power tools onsite, were suspended by the wire from the ceiling.     In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.403 I02 I

Serious Gravity 10 50 instances 1 exposed
Issued
Penalty
Initial $4900.00 · Current $0.00 Reduced
29 CFR 1926.403(i)(2)(i): Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by cabinets or other forms of enclosures, nor by any of the means listed in subparagraphs (A) through (D) of this paragraph:    a)  On or about October 17, 2012, employees were exposed to the electrical hazards where electrical panels did not have covers exposing them to accidental contact with live parts.     No abatement certification or documentation is required for this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $4900

1926.405 A02 II E

Serious Gravity 5 2 instances 1 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $0.00 Reduced
29 CFR 1926.405(a)(2)(ii)(E):  Lamps used in temporary wiring for general illumination were not protected from accidental contact or breakage:    a)  On or about October 17, 2012, the employer did not ensure that the lamps used in temporary wiring to illuminate the work areas throughout the building were protected from accidental contact or breakage.    In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (S) $0
  • — Z (S) $2800

1926.416 E01

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $3500.00 · Current $1695.00 Reduced
29 CFR 1926.416(e)(1):  Worn or frayed electric cords or cables were used:       a) On or about October 17, 2012, the insulation on the flexible cord powering equipment onsite was worn as evidenced by the exposed un-insulated conductors.     In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (S) $1695
  • — Z (S) $3500

1926.501 B04 II

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $2800.00 · Current $1355.00 Reduced
29 CFR 1926.501(b)(4)(ii):  Each employee on a walking/working surface was not protected from tripping in or stepping into or through holes (including skylights) by covers:     a)  On or about October 17, 2012, employees were not protected from the hazards of tripping or stepping into a hole while walking and working around unguarded floor holes.      No abatement certification or documentation is required for this item.
Recent events (2)
  • — I (S) $1355
  • — Z (S) $2800

View HORIZON GROUP MANAGEMENT, LLC's full OSHA safety record →