OSHA Inspection: JJL COMMERCIAL DEVELOPMENT, LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of JJL COMMERCIAL DEVELOPMENT, LLC in 5 WATSON ROAD, PRESTON, CT 06365 (NAICS 236220). OSHA activity number 336921580.

Watch JJL Commercial Development, LLC — free Get an email when a new federal OSHA severe-injury report for JJL Commercial Development, LLC is published. One employer, no account, unsubscribe in one click.
Site address
5 WATSON ROAD
City
PRESTON
State
CT
ZIP
06365
Mailing
276 THAMES STREET, GROTON, CT 06340
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236220
Employees
1
Ownership type
A

4 citations on file for this inspection.

1926.405 A02 II E

Serious Gravity 5 4 instances 1 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $1600.00
29 CFR 1926.405(a)(2)(ii)(E):  Lamps used in temporary wiring for general illumination were not protected from accidental contact or breakage:    a)  Hilton Hotel - 5 Watson Road, Preston, CT. - On or about 10-17-12 - First, Second, Third and Fourth floors had bulb guards and bulbs missing on temporary lighting system which exposed employees to electrical shock and burn hazards.
Recent events (1)
  • — Z (S) $1600

1926.416 A01

Serious Gravity 5 4 instances 1 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $1600.00
29 CFR 1926.416(a)(1):     Employees were permitted to work in proximity to electric power circuits and were not protected against electric shock by de-energizing and grounding the circuits or effectively guarding the circuits by insulation or other means:    a)  Hilton Garden Inn, 5 Watson Road - On or about 10-17-12 - Employees were exposed to electrical burn and shock hazard from temporary lighting systems that had missing bulb exposing metal socket and broken energized bulbs located near metal stair railing. Broken bulbs and exposed live parts were laying on metal railing system in the stairways used by all crafts on site.
Recent events (1)
  • — Z (S) $1600

1926.1052 B01

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $2400.00 · Current $2400.00
29 CFR 1926.1052(b)(1):   Foot traffic was not prohibited on stairways where the treads and/or landings of pan stairs were to be filled in with concrete or other material at a later date and stairs were not temporarily fitted with wood or other solid material at least to the top edge of each pan.    South Side Stairway - On or about 10-17-12 - Employees were observed using open pan metal stairway to access floors 1 through 4 of the building, that were not filled exposing employees to trip and fall hazards.
Recent events (1)
  • — Z (S) $2400

1926.1052 C01 II

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $1600.00 · Current $1600.00
29 CFR 1926.1052(c)(1)(ii):   Stairways having four or more risers or rising more than 30 inches (76 cm), whichever was less, were not equipped with one stairrail system along each unprotected side or edge:    a) Concrete Stairway at Northside Entrance - On or about 10-17-12 - Employee was observed using a stairway eight risers in height and six feet wide with no stairrail system installed.