SAPULPA, OK —
OSHA Inspection: THERMAL ENGINEERING INTERNATIONAL (USA), INC. A SUBSIDARY OF BABCOCK POWER
Federal Agency inspection · Safety discipline
At a glance
On , OSHA opened a federal Agency safety inspection of THERMAL ENGINEERING INTERNATIONAL (USA), INC. A SUBSIDARY OF BABCOCK POWER in 2110 N INDUDTRAIL ROAD, SAPULPA, OK 74066 (NAICS 332410). OSHA activity number 337215610.
Where did this inspection happen?
- Site address
- 2110 N INDUDTRAIL ROAD
- City
- SAPULPA
- State
- OK
- ZIP
- 74066
- Mailing
- 2110 N INDUSTRIAL ROAD, SAPULPA, OK 74066
What kind of inspection was it?
- Inspection type
- Federal Agency (M)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332410
- Employees
- 130
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.146 D09
- Issued
- Abate by
- Penalty
- Initial $7000.00 · Current $7000.00
General-duty citation text
29 CFR 1910.146(d)(9): The employer did not develop and implement procedures for summoning rescue and emergency service, for rescuing entrants from permit spaces, for providing necessary emergency services to rescued employees, and for preventing unauthorized personnel from attempting a rescue: On or about November 03, 2012, the employer did not ensure procedures for summoning rescue and emergency services, rescuing entrants from permit spaces, providing necessary emergency services to rescued employees or preventing unauthorized personnel from attempting a rescue to eliminate or control the hazards created when a permit-required confined space rescue was needed during welding operations conducted in the elliptical head of a moisture separator unit.
Recent events (2)
- — I (S) $7000
- — Z (S) $7000
1910.146 G01
- Issued
- Abate by
- Penalty
- Initial $7000.00 · Current $5000.00 Reduced
General-duty citation text
29 CFR 1910.146(g)(1): The employer did not provide training so that all employees whose work was regulated by 29 CFR 1910.146 (permit required confined spaces) acquired the understanding, knowledge, and skills necessary for the safe performance of the duties assigned under 29 CFR 1910.146: On or about November 03, 2012, the employer did not provide adequate training for employees (supervisors) who were authorized to issue permits for permit required confined spaces. Employee(s) were exposed to hazard of being caught in a confined space and/or lack of oxygen due to carbon monoxide.
Recent events (2)
- — I (S) $5000
- — Z (S) $7000
1910.146 J04
- Issued
- Abate by
- Penalty
- Initial $7000.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.146(j)(4): The employer did not ensure that each entry supervisor verified that rescue services were available and that the means for summoning them were operable: On or about November 03, 2012, the employer had not ensured that the entry supervisor had made verification of rescue services. Employee(s) were exposed to hazard of being caught in a confined space and/or lack of oxygen due to carbon monoxide while preforming welding in the elliptical head of a moisture separator unit.
Recent events (2)
- — I (S) $0
- — Z (S) $7000
More inspections in this industry (NAICS 332410)
ORANGEBURG, SC—2026-07-01
77560 - FLEXTRONICS
LEXINGTON, VA—2026-05-04
MODINE MANUFACTURING COMPANY
HICKORY, NC—2026-03-18
160746 - MAXIMIZER SYSTEMS, INC.
DELAWARE, OH—2026-02-17
ONDA USA LLC
FRANKLIN, PA—2026-02-11
WM. T. SPAEDER COMPANY
More inspections in OK
MADILL, OK—2026-07-08
MID AMERICAN STEEL & WIRE CO., LLC
SEILING, OK—2026-06-26
GORE ENERGY
ADA, OK—2026-06-25
PAN AMERICA ELECTRIC , INC.
ADA, OK—2026-06-25
CITATION OIL & GAS CORPORATION
EDMOND, OK—2026-06-23
BRICK EXPERTS INC.
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 337215610.