OSHA Inspection: BIG D ELECTRIC, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of BIG D ELECTRIC, INC. in SOUTH MARKET ROAD SOUTH OF LAKE OF EGYPT FIRE DISTRICT, MARION, IL 62959 (NAICS 238210). OSHA activity number 337394019.

Watch BIG D Electric, INC. — free Get an email when a new federal OSHA severe-injury report for BIG D Electric, INC. is published. One employer, no account, unsubscribe in one click.
Site address
SOUTH MARKET ROAD SOUTH OF LAKE OF EGYPT FIRE DISTRICT
City
MARION
State
IL
ZIP
62959
Mailing
P.O. BOX 156, ELDORADO, IL 62930
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238210
Employees
20
Ownership type
A

2 citations on file for this inspection.

1926.950 C01 I

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $2000.00 Reduced
29 CFR 1926.950(c)(1)(i):     No employee shall be permitted to approach or take any conductive object without an approved insulating handle closer to exposed energized parts than shown in Table V-1, unless the employee is insulated or guarded from the energized part (gloves or gloves with sleeves rated for the voltage involved shall be considered insulation of the employee from the energized part):        a)	On or about October 9, 2012, while working alongside the road way on South Market Road, Marion IL at the Lake of Egypt area, an employee working in a truck aerial lift, installing new transmission lines adjacent to existing 7.2 Kilovolt power lines, was wearing leather work gloves that are not insulated regarding electrical hazards.
Recent events (2)
  • — I (S) $2000
  • — Z (S) $2800

1926.952 B02

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $2000.00 Reduced
29 CFR 1926.952(b)(2):     Aerial lift trucks were not grounded or barricaded and considered as energized equipment when working near energized lines or equipment or the aerial lift truck shall be insulated for the work being performed:    a)	On or about October 9, 2012, while working alongside the road way on South Market Road, Marion IL at the Lake of Egypt area, employee was using the Altec aerial lift that had a missing insulated cover from its structure that insulated the metal structure components from electrical exposure.  The lift contacted the 7.2 Kilovolt power line which resulted in the employee receiving an electrical shock.