STATESBORO, GA —
OSHA Inspection: LACIO SILVA
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of LACIO SILVA in 552 EAST MAIN STREET, STATESBORO, GA 30458 (NAICS 238130). OSHA activity number 337643613.
Where did this inspection happen?
- Establishment
- LACIO SILVA
- Site address
- 552 EAST MAIN STREET
- City
- STATESBORO
- State
- GA
- ZIP
- 30458
- Mailing
- 1105 S. ROGERS STREET UNIT 524, POOLER, GA 31322
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 6
- Ownership type
- A
Citations
7 citations on file for this inspection.
1926.416 E01
- Issued
- Penalty
- Initial $1200.00 · Current $1200.00
General-duty citation text
29 CFR 1926.416(e)(1): Worn or frayed electric cords or cables were used: a) The Village at Mill Creek Subdivision, Lot 24 - On or about December 4, 2012, an orange flexible cord used to power a DeWalt circular saw had worn outer sheathing, exposing employees to an electrical shock hazard. ABATEMENT CERTIFICATION IS NOT REQUIRED
Recent events (1)
- — Z (S) $1200
1926.501 B13
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $2800.00
General-duty citation text
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels was not protected by guardrail systems, safety net systems, personal fall arrest systems, or an alternative fall protection measure under another provision of paragraph 1926.501 (b), nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502: a) The Village at Mill Creek Subdivision, Lot 24 - On or about November 30, 2012, employees installing floor joists were exposed to fall hazards up to approximately 11 feet, 8 inches onto earthen and concrete ground because the workers were not fall protected by conventional fall protection. b) The Village at Mill Creek Subdivision, Lot 24 - On or about December 4, 2012, employees erecting exterior walls were exposed to fall hazards up to approximately 11 feet, 8 inches onto earthen ground because the workers were not fall protected by conventional fall protection. ABATEMENT CERTIFICATION AND DOCUMENTATION IS REQUIRED
Recent events (1)
- — Z (S) $2800
1926.503 A01
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $2800.00
General-duty citation text
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: a) The Village at Mill Creek Subdivision, Lot 24 - On or about December 4, 2012, and at times prior to, the employer did not ensure employees engaged in framing / rough carpentry and were regularly exposed to fall hazards up to approximately 11 feet 8 inches were effectively trained to recognize the fall hazards encountered in their work. ABATEMENT CERTIFICATION AND DOCUMENTATION IS REQUIRED
Recent events (1)
- — Z (S) $2800
1926.1053 B01
- Issued
- Penalty
- Initial $1600.00 · Current $1600.00
General-duty citation text
29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend to at least 3 feet (.9m) above the upper landing surface to which the ladder was used to gain access nor was the ladder secured at it's top to a rigid support and a grasping device, such as a grabrail, provided to assist the employee in mounting and dismounting the ladder: a) The Village at Mill Creek Subdivision, Lot 24 - On or about November 30, 2012, employees used an aluminum extension ladder to gain access to the second story of an apartment building without the side rails of the ladder being extended at least 3 feet above the upper landing surface of the upper landing surface nor was the ladder secured at its top to a rigid support, exposing employees to fall hazards of up to approximately 11 feet, 8 inches onto earthen ground. b) The Village at Mill Creek Subdivision, Lot 24 - On or about December 4, 2012, employees used an aluminum extension ladder to gain access to the second story of an apartment building without the side rails of the ladder being extended at least 3 feet above the upper landing surface of the upper landing surface nor was the ladder secured at its top to a rigid support, exposing employees to fall hazards of up to approximately 11 feet, 8 inches onto earthen ground. ABATEMENT CERTIFICATION IS NOT REQUIRED
Recent events (1)
- — Z (S) $1600
1910.1200 E01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: (Construction Reference: 1926.59) a) The Village at Mill Creek Subdivision, Lot 24 - On or about December 4, 2012, the employer did not develop, implement, and/or maintain a written hazard communication program at the workplace, exposing employees to possible skin, eye, and respiratory irritations from chemicals including but not limited to ProLock Subfloor Adhesive being used to install floor sheathing and frame walls. ABATEMENT CERTIFICATION IS REQUIRED
Recent events (1)
- — Z (O) $0
1910.1200 G01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.1200(g)(1): The employer did not have a material safety data sheet for each hazardous chemical in use: a) The Village at Mill Creek Subdivision, Lot 24 - On or about December 4, 2012, the employer did not have a material safety data sheet for chemicals including but not limited to ProLock Subfloor Adhesive used to install floor sheathing, exposing employees to possible skin, eye, and respiratory irritations. ABATEMENT CERTIFICATION IS REQUIRED
Recent events (1)
- — Z (O) $0
1910.1200 H01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: a) The Village at Mill Creek Subdivision, Lot 24 - On or about November 30, 2012, employees were not provided with effective hazardous communication training, exposing employees to possible skin, eye, and respiratory irritations from chemicals including but not limited to ProLock Subfloor Adhesive being used to install floor sheathing and frame walls. ABATEMENT CERTIFICATION IS REQUIRED
Recent events (1)
- — Z (O) $0
More inspections in this industry (NAICS 238130)
FAIRHOPE, AL—2026-07-16 00:00:00
FRANCISCO ARES
WOODHAVEN, MI—2026-07-16 00:00:00
G.J. PERELLI CO., L.L.C.
PHILADELPHIA, PA—2026-07-16 00:00:00
URUS CONSTRUCTION CORPORATION
BERLIN, NJ—2026-07-16 00:00:00
URUS CONSTRUCTION CORPORATION
MERIDIAN, ID—2026-07-15 00:00:00
TRIPLE R CONSTRUCTION LLC
More inspections in GA
GREENSBORO, GA—2026-07-16 00:00:00
PURE BEAUTY FARMS, INC.
FOREST PARK, GA—2026-07-16 00:00:00
POLYNT COMPOSITES USA INC.
AUGUSTA, GA—2026-07-16 00:00:00
GF CASTING SOLUTIONS AUGUSTA, LLC
CHAMBLEE, GA—2026-07-16 00:00:00
U.S. DEPARTMENT OF TREASURY
DECATUR, GA—2026-07-15 00:00:00
PALLETS ACQUISITION LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 337643613.