Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: BRENCO CONSTRUCTION COMPANY INC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of BRENCO CONSTRUCTION COMPANY INC in 34 MAIN STREET, NORTH EASTON, MA 02357 (NAICS 238160). OSHA activity number 337972814.

Watch Brenco Construction Company INC — free Get an email when a new federal OSHA severe-injury report for Brenco Construction Company INC is published. One employer, no account, unsubscribe in one click.
Site address
34 MAIN STREET
City
NORTH EASTON
State
MA
ZIP
02357
Mailing
1094 ADAMS STREET, DORCHESTER, MA 02122
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
15
Ownership type
A

3 citations on file for this inspection.

1926.501 B14

Serious Gravity 10 8 instances 15 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $1400.00 Reduced
29 CFR 1926.501(b)(14):     "Wall openings." Each employee working on, at, above, or near wall openings (including those with chutes attached) where the outside bottom edge of the wall opening is 6 feet (1.8 m) or more above lower levels and the inside bottom edge of the wall opening is less than 39 inches (1.0 m) above the walking/working surface, shall be protected from falling by the use of a guardrail system, a safety net system, or a personal fall arrest system.      Jobsite:  Employees working on second floor were exposed to falls from second floor windows. Tthe end of the building doors was not properlly guarded with either top-rail or mid-rail, exposing employees to falls of 13 feet.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2800

1926.602 C01 II

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $1400.00 Reduced
29 CFR 1926.602(c)(1)(ii):     No modifications or additions which affect the capacity or safe operation of the equipment shall be made without the manufacturer's written approval. If such modifications or changes are made, the capacity, operation, and maintenance instruction plates, tags, or decals shall be changed accordingly. In no case shall the original safety factor of the equipment be reduced.        Jobsite:  Crews were using a Lull and replaced missing safety pins with threaded bolts,washers and nuts not approved by the manufacturer for safe handling procedures.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2800

1926.1052 C01

Serious Gravity 10 8 instances 15 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $1400.00 Reduced
29 CFR 1926.1052(c)(1):     Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with at least one handrail and one stairrail system along each unprotected side or edge:    Jobsite:  Employees working in the buildings and accessing the second floor were exposed to slips trips and falls due to no handrails installed in the units.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2800

View BRENCO CONSTRUCTION COMPANY INC's full OSHA safety record →