Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ROCKIN C SAWMILL

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ROCKIN C SAWMILL in 1536 ARKADELPHIA RD., PITKIN, LA 70656 (NAICS 321113). OSHA activity number 338185234.

Watch Rockin C Sawmill — free Get an email when a new federal OSHA severe-injury report for Rockin C Sawmill is published. One employer, no account, unsubscribe in one click.
Establishment
ROCKIN C SAWMILL
Site address
1536 ARKADELPHIA RD.
City
PITKIN
State
LA
ZIP
70656
Mailing
1536 ARKADELPHIA RD., PITKIN, LA 70656
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321113
Employees
14
Ownership type
A

6 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 5 4 instances 11 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $2000.00
29 CFR 1910.147(c)(4)(i): Procedures were not developed and documented for the control of potentially hazardous energy when employees were engaged in activities covered by this section.  The procedures shall clearly and specifically outline the means to enforce compliance including, but not limited to, the following:      a) 1536 Arkadelphia Rd., Pitkin, LA; the employer did not develop written procedures with specific steps for the control of potentially hazardous energy regarding machines and equipment such as, but not limited to:        1. Cut-off Deck        2. Debarker        3. Main Saw        4. Tie Stacker
Recent events (2)
  • — I (S) $2000
  • — Z (S) $2000

1910.212 A03 II

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $1200.00 · Current $1200.00
29 CFR 1910.212(a)(3)(ii): The point of operation of machines whose operation exposes an employee to injury, shall be guarded. The guarding device shall be in conformity with any appropriate standards therefor, or, in the absence of applicable specific standards, shall be so designed and constructed as to prevent the operator from having any part of his body in the danger zone during the operating cycle.      a) Electrical room; a Daytona drill press did not have a guard around the bit to prevent a point of operation injury.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $1200

1910.219 D01

Serious Gravity 5 2 instances 11 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $1600.00
29 CFR 1910.219(d)(1): Guarding. Pulleys, any parts of which are seven (7) feet or less from the floor or working platform, shall be guarded in accordance with the standards specified in paragraphs (m) and (o) of this section. Pulleys serving as balance wheels (e.g., punch presses) on which the point of contact between belt and pulley is more than six feet six inches (6 ft. 6 in.) from the floor or platform may be guarded with a disk covering the spokes.      a) Cut-off deck:        1. The pulley system that brings saw dust away from the deck was not guarded.         2. The pulley system on the long log deck of the cut-off deck was not guarded.       These conditions exposed employees to a caught-in/pinch-point hazard.
Recent events (2)
  • — I (S) $1600
  • — Z (S) $1600

1910.305 B01 II

Serious Gravity 5 2 instances 14 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $2000.00
29 CFR 1910.305(b)(1)(ii): Unused openings in cabinets, boxes, and fittings shall be effectively closed.      a) Electrical room:       1. Two electrical panels had uncovered circuit breaker openings.       2. Three breaker covers had openings in the cover.    These conditions exposed employees to possible contact with live electrical conductors and the hazard of electrical shock.
Recent events (2)
  • — I (S) $2000
  • — Z (S) $2000

1910.305 B02 I

Serious Gravity 10 5 instances 14 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $2800.00
29 CFR 1910.305(b)(2)(i): All pull boxes, junction boxes, and fittings shall be provided with covers identified for the purpose. If metal covers are used, they shall be grounded. In completed installations, each outlet box shall have a cover, faceplate, or fixture canopy. Covers of outlet boxes having holes through which flexible cord pendants pass shall be provided with bushings designed for the purpose or shall have smooth, well-rounded surfaces on which the cords may bear.      a) Hydraulic Room; Two electrical outlets and a light wall switch was missing the cover.    b) Cut-off deck; Two electrical boxes missing the cover. Electrical wires inside were exposed.    c) Electrical Room:        1. The electrical panel that housed the electrical circuits for the welder, trim saw, and the saw room was missing the cover.             Live/hot electrical wires are exposed.        2. Electrical panels on the front wall was missing the cover.    These conditions exposed employees to electric shock hazards.
Recent events (2)
  • — I (S) $2800
  • — Z (S) $2800

1904.29 B01

Other-than-serious 4 instances 14 exposed
Issued
Abate by
Penalty
Initial $400.00 · Current $400.00
29 CFR 1904.29(b)(1): A Log of Work-Related Injuries and Illnesses (OSHA Form 300) and the Summary of Work-Related Injuries and Illnesses (OSHA Form 300A) were not kept by the establishment:      a) 1536 Arkadelphia Rd., Pitkin, LA; The employer did not record work-related injuries and illnesses on the OSHA Form 300, nor did the employer complete the annual summary of injuries and illnesses on the OSHA Form 300A.  The employer did not have these required forms for recording injuries and illnesses for year(s) 2012, 2011, 2010, 2009 and 2008.  The forms are required to be maintained for five (5) years following the end of the calendar year that these records cover.
Recent events (2)
  • — I (O) $400
  • — Z (O) $400

View ROCKIN C SAWMILL's full OSHA safety record →