NAALEHU, HI —
OSHA Inspection: LAI, LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of LAI, LLC in 95-56442 MAMALAHOA HWY, NAALEHU, HI 96772 (NAICS 311812). OSHA activity number 338768666.
Where did this inspection happen?
- Establishment
- LAI, LLC
- Site address
- 95-56442 MAMALAHOA HWY
- City
- NAALEHU
- State
- HI
- ZIP
- 96772
- Mailing
- P.O. BOX 655, NAALEHU, HI 96772
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 311812
- Employees
- 31
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.263 E02 I
- Issued
- Abate by
- Penalty
- Initial $2975.00 · Current $1500.00 Reduced
General-duty citation text
29 CFR 1910.263(e)(2)(i): Vertical mixers did not comply with paragraphs (e)(1)(i), (iii), (ix), and (x) of this section and did not have all belts, chains, gears, pulleys, sprockets, clutches, and other moving parts completely enclosed: (a) Bakery area, Hobart mixer #1: The employer exposed employees to amputation hazards as the dough mixer was not equipped with a guard near the mixing blade. (b) Bakery area, Hobart mixer #2: The employer exposed employees to amputation hazards as the dough mixer was not equipped with a guard near the mixing blade. (c) Bakery area, Hobart mixer #3: The employer exposed employees to amputation hazards as the dough mixer was not equipped with a guard near the mixing blade. (d) Bakery area, Hobart mixer #4: The employer exposed employees to amputation hazards as the dough mixer was not equipped with a guard near the mixing blade.
Recent events (2)
- — I (S) $1500
- — Z (S) $2975
1910.263 J01 III
- Issued
- Abate by
- Penalty
- Initial $2975.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.263(j)(1)(iii): Cover(s) over the knife head of reciprocating blade slicer(s) were not provided with an interlocking arrangement so that the machine could not operate unless the cover was in place: (a) Bakery area, bread slicer: The employer exposed employees to amputation hazards as they were allowed to use a bread slicer that was missing an interlocked cover.
Recent events (2)
- — I (S) $0
- — Z (S) $2975
1910.303 G01
- Issued
- Abate by
- Penalty
- Initial $1785.00 · Current $1000.00 Reduced
General-duty citation text
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment: (a) Bakery area, Hobart mixer #2: The employer exposed employees to unsafe operation and maintenance of equipment as a dough mixer was obstructing an electrical disconnect panel.
Recent events (2)
- — I (S) $1000
- — Z (S) $1785
1910.305 B01 II
- Issued
- Abate by
- Penalty
- Initial $2975.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: (a) Bakery area, rotating oven: The employer exposed employees to electrical shock hazards of 110 volts as an electrical panel had a blank opening that was missing a fitting.
Recent events (2)
- — I (O) $0
- — Z (S) $2975
1910.305 G01 IV A
- Issued
- Abate by
- Penalty
- Initial $2975.00 · Current $1000.00 Reduced
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: (a) Bakery area, sheet machine: The employer used flexible cords as a substitute for fixed wiring to supply electricity to the sheet machine, exposing employees to fire and electrical shock hazards of 110 volts.
Recent events (2)
- — I (S) $1000
- — Z (S) $2975
1910.305 G01 IV D
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(D): Flexible cords were attached to building surfaces: (a) Bakery area, flexible cords to structure: The employer attached flexible cords to the building structure and allowed employees to work in close proximity, exposing them to electrical shock hazards of 480 volts.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections in this industry (NAICS 311812)
WOODBURN, OR—2026-07-14 00:00:00
317744771 - MIRANDA'S BAKERY CORP
LONGVIEW, WA—2026-07-10 00:00:00
WA317992033 - UNITED STATES BAKERY DBA FRANZ FAMILY BAKERIE
PATERSON, NJ—2026-07-09 00:00:00
MUFFINS 'N STUFF
GLENDALE, CA—2026-07-08 00:00:00
FREUND BAKING COMPANY
YONKERS, NY—2026-07-07 00:00:00
GREYSTON BAKERY INC.
More inspections in HI
LAHAINA, HI—2026-07-15 00:00:00
PALI KOA LLC
HONOLULU, HI—2026-07-14 00:00:00
KAIKAI WANG
KIHEI, HI—2026-07-13 00:00:00
AUMAKUA HOLDINGS LLC
HONOLULU, HI—2026-07-13 00:00:00
TOELL U.S.A. CORPORATION
HONOLULU, HI—2026-07-13 00:00:00
A ONE ELECTRIC LLC