TAMUNING, GU —
OSHA Inspection: HYATT HOTELS CORPORATION
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of HYATT HOTELS CORPORATION in 1155 PALE SAN VITORES ROAD, TAMUNING, GU 96913 (NAICS 721110). OSHA activity number 338797442.
Where did this inspection happen?
- Establishment
- HYATT HOTELS CORPORATION
- Site address
- 1155 PALE SAN VITORES ROAD
- City
- TAMUNING
- State
- GU
- ZIP
- 96913
- Mailing
- 1155 PALE SAN VITORES ROAD JAN-HENDRICK MEIDINGER - GENERAL MANAGER, TAMUNING, GU 96913
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 721110
- Employees
- 470
- Ownership type
- A
Citations
9 citations on file for this inspection.
1910.303 B01 II
- Issued
- Abate by
- Penalty
- Initial $3000.00 · Current $2500.00 Reduced
General-duty citation text
29 CFR 1910.303(b)(1)(ii): Mechanical strength and durability, including, for parts designed to enclose and protect other equipment, the adequacy of the protection thus provided: LaMiranda Kitchen: On February 12, 2013, and at times prior thereto, the Star Pro Max Panini Grill power cord was pulled form its fiittng and the live inner conductors were exposed.
Recent events (2)
- — I (S) $2500
- — Z (S) $3000
1910.303 F02
- Issued
- Abate by
- Penalty
- Initial $3000.00 · Current $2500.00 Reduced
General-duty citation text
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident: On February 12, 2013, and at times prior thereto, disconnect boxes had no markings which indicated its purpose in the following locations; A. Plant Room: Two disconnects installed near the heat machines, which energized lights and outlets. B. Niji Japanese Kitchen: Two disconnects near the dishwashing area, which energized unknown equipment.
Recent events (2)
- — I (S) $2500
- — Z (S) $3000
1910.305 B01 II
- Issued
- Abate by
- Penalty
- Initial $4000.00 · Current $3000.00 Reduced
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: On February 12, 2013, and at times prior thereto, electrical equipment was not properly guarded and live wiring was exposed in the following locations; A. Cooling Tower 1-2: Two knockouts were missing in the junction box CT1-2 each leaving a one inch opening and exposing live inner conductors. B. LaMiranda Kitchen: The Tork Timer was missing an inner guard and the live inner conductors were exposed.
Recent events (2)
- — I (S) $3000
- — Z (S) $4000
1910.305 G01 IV A
- Issued
- Abate by
- Penalty
- Initial $3000.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: Niji Kitchen Electrical Closet: On February 12, 2013, and at times prior thereto, a blue extension cords was used in lieu of permanent wiring to energize a strand lighting dimmer system.
Recent events (2)
- — I (S) $0
- — Z (S) $3000
1910.305 G01 IV D
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(D): Flexible cords and/or cables were attached to building surfaces: Niji Kitchen Electrical Closet: On February 12, 2013, and at times prior thereto, a blue extension cords was attached to the building surface to energize a strand lighting dimmer system.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1200 F05 I
- Issued
- Abate by
- Penalty
- Initial $4000.00 · Current $3000.00 Reduced
General-duty citation text
29 CFR 1910.1200(f)(5)(i): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the identity of the hazardous chemical(s) contained therein: Pool Pump Room: On February 12, 2013, and at times prior thereto, a 50 gallon container of corrosive muriactic acid was not properly marked.
Recent events (2)
- — I (S) $3000
- — Z (S) $4000
1910.1200 F05 II
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.1200(f)(5)(ii): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the appropriate hazard warnings: Pool Pump Room: On February 12, 2013, and at times prior thereto, a 50 gallon container of corrosive muriactic acid was not properly marked.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.132 D02
- Issued
- Abate by
- Penalty
- Initial $200.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.132(d)(2): The employer did not verify, through a written certification, that the required workplace hazard assessment had been performed: Facility: On February 12, 2013, and at times prior thereto, the employer did not certify a written PPE Hazard Assessment had been preformed. The Hyatt Regency Guam was previously cited for a violation of this occupational safety and health standard 29 CFR 1910.132(d)(2) which was contained in OSHA Inspection Number 315278275, Citation Number 02, Item Number 002, issued on 07/22/2011, with respect to a workplace located at 1155 Pale San Vitores Road, Tumon Bay, Guam, which became final order on 08/08/2011.
Recent events (2)
- — I (R) $0
- — Z (R) $200
1910.1200 E01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: Facility: On February 12, 2013, and at times prior thereto, the employer did not develop or maintain a written Hazard Communication Program for employees who were exposed to hazardous chemicals including but not limited to; corrosive water treatment chemicals and irritative cleaning chemicals.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at HYATT HOTELS CORPORATION
BOSTON, MA—2018-01-26 00:00:00
HYATT HOTELS CORPORATION
TAMUNING, GU—2015-04-09 00:00:00
HYATT HOTELS CORPORATION
View HYATT HOTELS CORPORATION's full OSHA safety record →
More inspections in this industry (NAICS 721110)
LAS VEGAS, NV—2026-07-13
THE BERKLEY LAS VEGAS
LYNCHBURG, VA—2026-07-10
RIVERFRONT HOSPITALITY LLC
INCLINE VILLAGE, NV—2026-07-09
SHANTI RAHM LLC.
INCLINE VILLAGE, NV—2026-07-09
SHANTI RAHM LLC.
ISELIN, NJ—2026-07-09
DELTA HOTELS WOODBRIDGE
More inspections in GU
BARRIGADA, GU—2026-01-22
DURI CORPORATION
TAMUNING, GU—2026-01-21
DLR CORPORATION
BARRIGADA, GU—2026-01-21
DURI CORPORATION
TAMUNING, GU—2026-01-20
MG CONSTRUCTION COMPANY
BARRIGADA, GU—2026-01-20
PFM -VERTEX-LMS
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338797442.