OSHA Inspection: KOTULSKI DRYWALL

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of KOTULSKI DRYWALL in CORNER OF GRIMES AVE AND DEPOSITION AVE, CLEAR LAKE, WI 54005 (NAICS 238310). OSHA activity number 338813033.

Watch Kotulski Drywall — free Get an email when a new federal OSHA severe-injury report for Kotulski Drywall is published. One employer, no account, unsubscribe in one click.
Establishment
KOTULSKI DRYWALL
Site address
CORNER OF GRIMES AVE AND DEPOSITION AVE
City
CLEAR LAKE
State
WI
ZIP
54005
Mailing
N2740 CEDAR SWAMP ROAD, WEYERHAEUSER, WI 54895
Inspection type
Unprogrammed Other (I)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238310
Employees
3
Ownership type
A

6 citations on file for this inspection.

1926.404 B01 I

Serious Gravity 1 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $1200.00 · Current $840.00 Reduced
29 CFR 1926.404(b)(1)(i): Employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section, or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites.  a) Construction site located at First Lutheran Church in Clear Lake, WI; Ground fault circuit interruption was not provided.  Damaged extension cord sets were used to provide electrical power for corded hand held power tools.
Recent events (2)
  • — I (S) $840
  • — Z (S) $1200

1926.405 G02 III

Serious Gravity 1 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.405(g)(2)(iii): The repair splice in a hard service flexible cord No. 12 or larger did not retain the insulation, outer sheath properties, and usage characteristics of the cord which was being used:  a) Construction site located at First Lutheran Church in Clear Lake, WI; Electrical tape was used to repair physical damage on several extension cord sets.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.405 G02 IV

Serious Gravity 1 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws:  a) Construction site located at First Lutheran Church in Clear Lake, WI; Strain relief was not provided for a flexible cord end on a DeWalt brand radio.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.405 B02

Serious Gravity 1 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $1200.00 · Current $0.00 Reduced
29 CFR 1926.405(b)(2): In energized installations, each outlet box did not have a cover, faceplate, or fixture canopy:  a) Construction site located at First Lutheran Church in Clear Lake, WI; Cover plates were not provided for energized 120 volt receptacles.
Recent events (2)
  • — I (S) $0
  • — Z (S) $1200

1926.1053 B04

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $1200.00 · Current $840.00 Reduced
29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed:  (a) Construction site located at First Lutheran Church in Clear Lake, WI; A six foot step ladder was not setup in the open position prior to being used for supporting a scaffold plank.
Recent events (2)
  • — I (S) $840
  • — Z (S) $1200

1926.1060 A01 III

Serious Gravity 1 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.1060(a)(1)(iii): The employer did not ensure that each employee using ladders and/or stairways had been trained by a competent person in the proper construction, use, placement, and care in handling the ladders and/or stairways:  (a) Construction site located at First Lutheran Church in Clear Lake, WI; Training was not provided for ladder use, placement, and handling prior to employees using ladders as part of a supported scaffold system.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338813033.