Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,645Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: NEW CUT TOOL & MFG CORP.

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of NEW CUT TOOL & MFG CORP. in 55861 NEW CUT RD, SHADYSIDE, OH 43947 (NAICS 332710). OSHA activity number 338907744.

Watch NEW CUT Tool & MFG Corp. — free Get an email when a new federal OSHA severe-injury report for NEW CUT Tool & MFG Corp. is published. One employer, no account, unsubscribe in one click.
Site address
55861 NEW CUT RD
City
SHADYSIDE
State
OH
ZIP
43947
Mailing
55861 NEW CUT RD, SHADYSIDE, OH 43947
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332710
Employees
13
Ownership type
A

5 citations on file for this inspection.

1910.134 C01

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $1360.00 · Current $952.00 Reduced
29 CFR 1910.134(c)(1):     In any workplace where respirators are necessary to protect the health of the employee or whenever respirators are required by the employer, the employer shall establish and implement a written respiratory protection program with worksite-specific procedures. The program shall be updated as necessary to reflect those changes in workplace conditions that affect respirator use. The employer shall include in the program the following provisions of this section, as applicable:    (a) At the work site located at 55861 New Cut Road, Shadyside, Ohio, the employer required two employees to wear half-face respirators when blasting machine parts.  The employer did not have a written respiratory protection program.
Recent events (2)
  • — I (S) $952
  • — Z (S) $1360

1910.134 E01

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.134(e)(1):     General. The employer shall provide a medical evaluation to determine the employee's ability to use a respirator, before the employee is fit tested or required to use the respirator in the workplace. The employer may discontinue an employee's medical evaluations when the employee is no longer required to use a respirator.    a.  At the work site located at 55861 New Cut Road, Shadyside, Ohio, the employer did not have two employees medically cleared prior to wearing respiratory protection required at the job site.  The employees wore half face respirators while they blasted machine parts prior to painting and refurbishing them.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 F

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.134(f):     Fit testing. This paragraph requires that, before an employee may be required to use any respirator with a negative or positive pressure tight-fitting facepiece, the employee must be fit tested with the same make, model, style, and size of respirator that will be used. This paragraph specifies the kinds of fit tests allowed, the procedures for conducting them, and how the results of the fit tests must be used.      a.  At the work site located at 55861 New Cut Road, Shadyside, Ohio, the employer required two employees who blasted machine parts to wear respiratory protection.  The employer did not have employees fit tested prior to wearing respiratory protection.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 G01 I A

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.134(g)(1)(i)(A):     Respirators with tight-fitting facepieces were worn by employees who had facial hair that came between the sealing surface of the facepiece and the face or that interfered with valve function:    (a) At the work site located at 55861 New Cut Road, Shadyside, Ohio, the employer allowed two unshaven employees to wear half-face respirators when blasting machine parts.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 H01 II

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.134(h)(1)(ii):     Respirators issued to more than one employee shall be cleaned and disinfected before being worn by different individuals;    (a) At the work site located at 55861 New Cut Road, Shadyside, Ohio, the employer required employees to wear a half-face respirator when blasting machine parts in an exterior part of the work site.  The employees shared one half-face respirator that was not always cleaned and disinfected after use.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0