OSHA Inspection: BLAINE MASONRY INC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of BLAINE MASONRY INC in EDWARDS FARMS ROAD AND CAMDEN PLACE DRIVE, COLUMBUS, OH 43016 (NAICS 238140). OSHA activity number 338933955.

Watch Blaine Masonry INC — free Get an email when a new federal OSHA severe-injury report for Blaine Masonry INC is published. One employer, no account, unsubscribe in one click.
Establishment
BLAINE MASONRY INC
Site address
EDWARDS FARMS ROAD AND CAMDEN PLACE DRIVE
City
COLUMBUS
State
OH
ZIP
43016
Mailing
326 SOUTH MAIN STREET PO BOX 148, SINKING SPRING, OH 45172
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
20
Ownership type
A

4 citations on file for this inspection.

1926.451 B01

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $1400.00 Reduced
29 CFR 1926.451(b)(1):     Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports.    a.  At the site, employees were performing masonry work from an approximately 18 foot tall tubular welded frame scaffold that was not fully planked exposing them to a fall hazard.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2800

1926.451 G01

Serious Gravity 5 1 instance 10 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $1000.00 Reduced
29 CFR 1926.451(g)(1):     Each employee on a scaffold more than 10 feet (3.1 m) above a lower level shall be protected from falling to that lower level.     a.  At the site, employees were performing masonry work from a tubular welded frame scaffold that was not equipped with fall protection.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2000

1926.451 G04 I

Serious Gravity 5 1 instance 10 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $1000.00 Reduced
29 CFR 1926.451(g)(4)(i):     Guardrail systems shall be installed along all open sides and ends of platforms. Guardrail systems shall be installed before the scaffold is released for use by employees other than erection/dismantling crews.    a.  At the site, employees were performing masonry work from a tubular welded frame scaffold that did not have guardrails installed on the ends of the scaffold, thereby exposing the employees to a fall hazard of approximately 18 feet.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2000

1926.452 C02

Serious Gravity 5 3 instances 10 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $1000.00 Reduced
29 CFR 1926.452(c)(2):     Frames and panels shall be braced by cross, horizontal, or diagonal braces, or combination thereof, which secure vertical members together laterally. The cross braces shall be of such length as will automatically square and align vertical members so that the erected scaffold is always plumb, level, and square. All brace connections shall be secured.    a.  At the site, employees were performing masonry work from an approximately 18 feet tall tubular welded frame scaffold that had brace connections not secured exposing them to a fall hazard.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2000