SARASOTA, FL —
OSHA Inspection: L&M SARASOTA LLC
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of L&M SARASOTA LLC in 1570 N. WASHINGTON BLVD, SARASOTA, FL 34236 (NAICS 811121). OSHA activity number 338935760.
Where did this inspection happen?
- Establishment
- L&M SARASOTA LLC
- Site address
- 1570 N. WASHINGTON BLVD
- City
- SARASOTA
- State
- FL
- ZIP
- 34236
- Mailing
- 1570 N. WASHINGTON BOULEVARD, SARASOTA, FL 34236
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 811121
- Employees
- 13
- Ownership type
- A
Citations
8 citations on file for this inspection.
1910.106 D04 I
- Issued
- Abate by
- Penalty
- Initial $1200.00 · Current $450.00 Reduced
General-duty citation text
29 CFR 1910.106(d)(4)(i): Inside storage rooms with openings to other rooms or buildings were not provided with approved self-closing fire doors: a. for the storage room located in the south east corner of the building at 1570 N Washington Boulevard in Sarasota (FL). Hazard observed on or about 03/05/2013.
Recent events (2)
- — I (S) $450
- — Z (S) $1200
1910.106 D04 III
- Issued
- Abate by
- Penalty
- Initial $1200.00 · Current $450.00 Reduced
General-duty citation text
29 CFR 1910.106(d)(4)(iii): Electrical wiring and equipment located in inside storage rooms used for Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 degrees Fahrenhiet (37.8 degrees Celcius), was not approved under subpart S of this part for Class I, Division 2 Hazardous Locations: a. for the storage room located in the south east corner of the building at 1570 N Washington Boulevard in Sarasota (FL), in that, the light bulb was missing the light fixture cover compromising the safety of the electrical installation per 29 CFR 1910.307. Hazard observed on or about 03/05/2013.
Recent events (2)
- — I (S) $450
- — Z (S) $1200
1910.106 D07 I A
- Issued
- Abate by
- Penalty
- Initial $1020.00 · Current $350.00 Reduced
General-duty citation text
29 CFR 1910.106(d)(7)(i)(a): There was not at least one portable fire extinguisher having a rating of not less than 12-B units located outside of, but not more than 10 feet from, the door opening into any room used for storage: a. in that a fire extinguisher was located more than 20 feet from the storage room located in the south east corner of the building at 1570 N Washington Boulevard in Sarasota (FL). Hazard observed on or about 03/05/2013.
Recent events (2)
- — I (S) $350
- — Z (S) $1020
1910.106 E02 II
- Issued
- Abate by
- Penalty
- Initial $1200.00 · Current $450.00 Reduced
General-duty citation text
29 CFR 1910.106(e)(2)(ii): Flammable or combustible liquids were not stored in tanks or closed containers: a. on or about 03/05/2013, for the storage room located in the south east corner of the building at 1570 N Washington Boulevard in Sarasota (FL): 1. one 55 gallon drum for used thinner storage was not closed, and 2. one 55 gallon drum for hazardous waste residue from recycled thinner was not closed.
Recent events (2)
- — I (S) $450
- — Z (S) $1200
1910.106 E06 II
- Issued
- Abate by
- Penalty
- Initial $1200.00 · Current $450.00 Reduced
General-duty citation text
29 CFR 1910.106(e)(6)(ii): Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 degrees Fahrenheit (37.8 degrees Celcius), were dispensed into containers without the nozzle and container being electrically interconnected. a. on or about 03/05/2013, for the storage room located in the south east corner of the building at 1570 N Washington Boulevard in Sarasota (FL), in that, one 55 gallon for hazardous waste residue from recycled thinner was not grounded.
Recent events (2)
- — I (S) $450
- — Z (S) $1200
1910.1200 G08
- Issued
- Abate by
- Penalty
- Initial $1020.00 · Current $350.00 Reduced
General-duty citation text
29 CFR 1910.1200(g)(8): The employer did not ensure that material safety data sheets were readily accessible to the employees in their work area during each work shift: a. for chemicals used during the sanding and prepping operations including flammable fillers Smart Duraglass at 1570 N Washington Boulevard in Sarasota (FL). Hazard observed on or about 03/05/2013.
Recent events (2)
- — I (S) $350
- — Z (S) $1020
1910.1200 H01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: (Construction Reference: 1926.59) a. for chemicals used during the sanding, prepping and painting operations including, but not limited to, flammable fillers Smart Duraglass, tints, toners, binders, activators, reducers, and clears from DuPont Nason products at 1570 N Washington Boulevard in Sarasota (FL). Hazard observed on or about 03/05/2013.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 C01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: a. at 1570 N Washington Boulevard in Sarasota (FL) for employees requires to use a half face tight-fit respirator with organic vapor cartridges and a particulate pre-filter. As observed on or about 03/05/2013.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 811121)
RIPON, WI—2026-07-15 00:00:00
SENECA FOODS CORPORATION
PORTLAND, OR—2026-07-13 00:00:00
317744734 - ATC AUTOBODY & PAINT LLC
SUMMIT, IL—2026-07-08 00:00:00
BUDS BODY SHOP SUPPLY & PAINT
PUYALLUP, WA—2026-07-08 00:00:00
WA317991990 - GLASS WORKS PRO INC
SALEM, VA—2026-07-08 00:00:00
CERTIFIED COLLISION REPAIR
More inspections in FL
MARIANNA, FL—2026-07-16 00:00:00
BRANNON BROTHERS CONSTRUCTION, LLC
LAKELAND, FL—2026-07-16 00:00:00
SOUTHERN MILLING & LUMBER, INC.
OAKLAND PARK, FL—2026-07-16 00:00:00
PKB CABINETRY
LAKELAND, FL—2026-07-16 00:00:00
ELIJAH WHOLESALE, LLC.
TAMPA, FL—2026-07-16 00:00:00
VALENCIA WHOLESALE, INC.
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338935760.