Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: PURVIS JEWELERS

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of PURVIS JEWELERS in 9190 WEST COLFAX AVE, LAKEWOOD, CO 80215 (NAICS 339913). OSHA activity number 338957517.

Watch Purvis Jewelers — free Get an email when a new federal OSHA severe-injury report for Purvis Jewelers is published. One employer, no account, unsubscribe in one click.
Establishment
PURVIS JEWELERS
Site address
9190 WEST COLFAX AVE
City
LAKEWOOD
State
CO
ZIP
80215
Mailing
9190 WEST COLFAX AVE, LAKEWOOD, CO 80215
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
339913
Employees
6
Ownership type
A

26 citations on file for this inspection.

5(a)(1)

Serious Gravity 5 3 instances 5 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to burn and fire hazards during gold melting operations:  a) On or about March 13, 2013, and at times prior, the employer did not ensure employees were protected from fire and burn hazards while melting gold with a propane torch, which produces a large open flame, on a counter top cluttered with flammable chemicals and other substances and under a shelf stacked with paper.    Abatement Note: Abatement certification and documentation are required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

5(a)(1)

Serious Gravity 5 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $1200.00 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the hazard associated with storing incompatible chemicals together:       (a) On or about March 20, 2013 and at times prior, containers of sulfuric acid and cyanide containing mixtures were stored next to one another in the jewelers' work area, exposing employees to hazards associated with hydrogen cyanide gas.     Abatement Note: Abatement certification and documentation are required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2000

5(a)(1)

Serious Gravity 5 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which was free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to injuries caused by high pressure steam:  (a) On or about March 20, 2013, and at times prior, employees were exposed to burn hazards associated with high pressure steam when an overpressure valve on a Hoffman New Yorker Steam Generator was pointed at a workstation at eye/face level.   Abatement Note: Abatement certification and documentation are required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.22 A01

Serious Gravity 5 3 instances 5 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms or service rooms were not kept clean and orderly or in a sanitary condition:  a) On or about March 13, 2013, and at times prior, the employer did not ensure the jeweler's work area was clean and orderly exposing employees to slip, trip, and fall hazards.   Abatement Note: Abatement certification and documentation are required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.101 B

Serious Gravity 5 2 instances 5 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.101(b): The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks were not in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in 29 CFR 1910.6:  (a) On or about March 13, 2013, and at times prior, employees were exposed to fire and explosion hazards in that the employer stored and used an oxygen cylinder directly below a natural gas spigot and a wax melting oven that was operational.  Section 3.3.5 of the Compressed Gas Association Pamphlet P-1-1965 states, "Cylinders should not be stored at temperatures above 125 F, nor near radiators or other sources of heat."  Section 3.3.6 states, "Do not store cylinders near highly flammable substances such as oil, gasoline, or waste." Section 3.5.1 states, "Do not store cylinders near highly flammable solvents, combustible waste material and similar substances."   (b) On or about March 13, 2013, and at times prior, employees were exposed to fire and burn hazards from cracked and deteriorating oxygen cylinder hoses. Section 3.4.12 of the Compressed Gas Association Pamphlet P-1-1965 states, "connections to piping, regulators, and other appliances should always be kept tight to prevent leakage. Where hose is used, it should be kept in good condition."    Abatement Note:  Abatement certification and documentation are required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.106 D05 III

Serious Gravity 5 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.106(d)(5)(iii): Storage of chemicals not required and used for maintenance and operation of building and operation of equipment was not prohibited. Such storage was not kept in closed metal containers, stored in a storage cabinet, or in safety cans, or in an inside storage room not having a door that opens into that portion of the building used by the public:  (a) On or about March 13, 2013, and at times prior, employees were exposed to explosion and fire hazards in that the employer stored flammable and combustible chemicals under a counter with heat sources (steamer with an over pressure release, and hot pots), sparking source (steamer), and electrical sources in the jeweler's work area, including but not limited to acetone, denatured alcohol, and xylene.  Abatement Note:  Abatement certification and documentation are required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.106 E06 I

Serious Gravity 5 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.106(e)(6)(i): Adequate precautions were not taken to prevent the ignition of flammable vapors from sources such as open flames; lightning; smoking; cutting and welding; hot surfaces; frictional heat; static, electrical, and mechanical sparks; spontaneous ignition, including heat-producing chemical reactions; and radiant heat:  (a) On or about March 20, 2013, and at times prior, the employer did not control or eliminate sources of ignition including radiant heat and static electricity in areas where flammable and combustible liquids were stored, including but not limited to xylene acetone, and denatured alcohol.   Abatement Note: Abatement certification and documentation are required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.110 B06 I

Serious Gravity 5 1 instance 6 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.110(b)(6)(i): Containers and first stage regulating equipment of liquid petroleum gases were not located outside of the building:  (a) On or about March 20, 2013, and at times prior, the employer used and stored a liquid propane cylinder inside the work area, exposing employees to fire, explosion, and struck-by hazards.  Abatement Note:  Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.133 A01

Serious Gravity 5 2 instances 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.133(a)(1): The employer did not ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation:  (a) On or about March 20, 2013, and at times prior, the employer did not ensure that employees using the Gesswein Jeweler's electric tools, which have a warning to wear eye protection while using the tools.    (b) On or about March 20, 2013, and at times prior, the employer did not provide appropriate eye and face protection to prevent injury while using corrosive and caustic chemicals and solvents, including but not limited to, hydrochloric acid, nitric acid, acetone and xylene.  Abatement Note:  Abatement certification and documentation are required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.138 A

Serious Gravity 5 2 instances 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.138(a): The employer did not select and require employee(s) to use appropriate hand protection when employees' hands were exposed to hazards such as those from skin absorption of harmful substances; severe cuts or lacerations; severe abrasion; punctures; chemical burns; thermal burns; and harmful temperature extremes:   (a) On or about March 20, 2013, and at times prior, employees were exposed to burns, lesions, sensitizations and other deleterious skin effects associated with caustic and/or corrosive chemicals where the employer did not provide the proper hand protection.    (b) On or about March 20, 2013, and at times prior, employees were exposed to thermal burns from direct and scattered infrared Class 4 laser radiation while using a Rofin laser etch tool without proper hand protection.  Abatement Note:  Abatement certification and documentation are required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.132 D01

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.132(d)(1): The employer did not assess the workplace to determine if hazards are present, or are likely to be present, which necessitate the use of personal protective equipment (PPE):  (a) On or about March 20, 2013, and at times prior, the employer did not conduct a hazard assessment and then provide equipment necessary to ensure employees were protected from the identified hazards.   Abatement Note:  Abatement certification and documentation are required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.141 G02

Serious Gravity 5 1 instance 6 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $1200.00 Reduced
29 CFR 1910.141(g)(2): Employees were permitted to consume food or beverage in area(s) exposed to toxic materials:    (a) On or about March 13, 2013, and at times prior, employees were exposed to chemical hazards where food and beverage were stored and consumed in the area where hazardous chemicals were being used.      Abatement Note:  Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2000

1910.151 C

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use:  (a) On or about March 20, 2013, and at times prior, employees were exposed to sulfuric acid, nitric acid, hydrochloric acid, and sodium hydroxide during jewelry making operations where no means of immediate drenching or flushing of the eyes and body were available.   Abatement Note: Abatement certification and documentation are required for this item (See enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 B02

Serious Gravity 5 3 instances 5 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  a) On or about March 13, 2013, and at times prior, the employer did not protect employees from shock and burn hazards from a light switch that was not properly installed and that had exposed conductors on the stone cutter along the north wall of the southeast alcove of the jeweler's work area.    b) On or about March 13, 2013, and at times prior, employees were exposed to fire hazards in that the employer did not know if each of the relocateable power taps, which are used heavily throughout the facility, was able to support the load placed on it.   c) On or about March 13, 2013, and at times prior, employees were exposed to fire hazards from a kitchen grade appliance was used for industrial chemical use.    Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 B07 IV

Serious Gravity 5 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.303(b)(7)(iv): There were damaged parts that adversely affected safe operation or mechanical strength of the equipment, such as parts that were broken, bent, cut, or deteriorated by corrosion, chemical action, or overheating:  a) On or about March 13, 2013, and at times prior, the employer did not protect employees from shock, burn, and fire hazards from a plug that was in use and was covered with paper in the grinder/polisher room.     Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.304 F01 VIII

Serious Gravity 5 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.304(f)(1)(viii): Circuit breakers used as switches in 120-volt and 277-volt, fluorescent lighting circuits were not listed and marked "SWD":  a)  On or about March 13, 2013, and at times prior, employees were exposed to fire and arcing hazards in that lights and other electrical equipment were turned on and off by using the circuit breakers not marked as "SWD" rather than light switches or other specific on/off switches, including but not limited to circuit breakers identified as 9, 11, 18 (hot plate), 20 (west track lighting), and 22.  Abatement Note: Abatement certification and documentation are required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 J01 I

Serious Gravity 5 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(j)(1)(i): Fixtures, lampholders, lamps, rosettes, and receptacles located within 8 feet of the floor had live parts exposed to employee contact:  (a) On or about March 13, 2013, and at times prior, employees were exposed to burn and fire hazards from and unguarded fluorescent light that was less than eight feet above the ground over a counter on the west side of the jewelers' work area.     Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.334 A01

Serious Gravity 5 1 instance 5 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.334(a)(1): Flexible electric cords were fastened with staples or otherwise hung in such a fashion as could damage the outer jacket or insulation:  (a) On or about March 20, 2013, and at times prior, employees were exposed to shock and fire hazards from an extension cord that was attached to the wall with thumb tacks that were stuck through it on the east wall of the show room.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.334 A02 I

Serious Gravity 5 2 instances 5 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.334(a)(2)(i): Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket):  (a) On or about March 20, 2013, and at times prior, employees were exposed to shock and fire hazards from a cord plugged into a lose outlet box in a display case on the west side of the show room that had broken insulation.   (b) On or about March 20, 2013, and at times prior, employees were exposed to shock and fire hazards from a cord with broken insulation that powered the grinder/polisher in the polisher room along the east wall next to the dust collector.     Abatement Note:  Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1200 E01

Serious Gravity 10 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $1600.00 Reduced
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met:    a) On or about March 20, 2013, and at times prior, the employer did not develop a written hazard communication program describing how the criteria for chemical labeling, material safety data sheets, and employee training will be met for hazardous chemicals used in the workplace.    Abatement Note: Abatement certification and documentation are required for this item (See enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (S) $1600
  • — Z (S) $2800

1910.1200 F05 I

Serious Gravity 10 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.1200(f)(5)(i): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the identity of the hazardous chemical(s) contained therein:  (a) On or about March 20, 2013, and at times prior, employees were exposed to hazardous chemicals stored in bottles with inadequate identification of the contents including but not limited to plating salts solutions, investments powder and sulfuric acid.   Abatement Note: Abatement certification and documentation are required for this item (See enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1200 F05 II

Serious Gravity 10 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.1200(f)(5)(ii): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the appropriate hazard warnings:  (a) On or about March 20, 2013, and at times prior, employees were exposed to hazardous chemicals stored in bottles with inadequate identification of the hazards of the contents including but not limited to plating salts solutions, investments powder and sulfuric acid.   Abatement Note: Abatement certification and documentation are required for this item (See enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.212 A01

Other-than-serious 2 instances 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  (a)  On or about March 20, 2013, and at times prior, the employer did not protect employees from rotating parts and flying debris in that the centrifuge was operated without a lid.    Abatement Note:  Abatement certification and documentation are required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.219 E01 I

Other-than-serious 2 instances 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.219(e)(1)(i): Horizontal belts which had both runs 42 inches or less from the floor level were not fully enclosed by guards conforming to requirements specified in 29 CFR 1910.219(m) and (o):   (a) On or about March 20, 2013, and at times prior, the employer did not protect employees from the in-going nip points and rotating parts of the belt and pully on the vacuum located on the ground near the sink in the jeweler's work area.   Abatement Note:  Abatement certification and documentation are required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.303 F02

Other-than-serious 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident:  (a) On or about March 13, 2013, and at times prior, employees were exposed to fire hazards in that the employer did not ensure circuit breakers were legibly labeled in the circuit breaker box next to the exit door in the jewelers' work room.    Abatement Note:  Abatement certification and documentation are requried for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.303 G01

Other-than-serious 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment:  (a) On or about March 13, 2013, and at times prior, employees were exposed to fire hazards in that the employer did not maintain a clear distance of three feet under and in front of the electrical panels to permit safe operation and maintenance of equipment.    Abatement Note:  Abatement certification and documentation are required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View PURVIS JEWELERS's full OSHA safety record →