Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: PREFINISHED STAINING PRODUCTS INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of PREFINISHED STAINING PRODUCTS INC. in 4575 ANSTON RD., GREEN BAY, WI 54313 (NAICS 321999). OSHA activity number 338967219.

Watch Prefinished Staining Products INC. — free Get an email when a new federal OSHA severe-injury report for Prefinished Staining Products INC. is published. One employer, no account, unsubscribe in one click.
Site address
4575 ANSTON RD.
City
GREEN BAY
State
WI
ZIP
54313
Mailing
P.O. BOX 10912, GREEN BAY, WI 54305
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321999
Employees
4
Ownership type
A

6 citations on file for this inspection.

1910.37 A03

Serious Gravity 5 1 instance 4 exposed
Issued
Penalty
Initial $2000.00 · Current $1000.00 Reduced
29 CFR 1910.37(a)(3):     Exit route(s) were not kept free and unobstructed:     (a)  On or about 3/20/2013, an emergency exit route was not kept free and unobstructed, as the emergency exit door on the west side of the facility had snow blocking it.         NO ABATEMENT CERTIFICATION OR DOCUMENTATION REQUIRED
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2000

1910.178 P01

Serious Gravity 5 2 instances 4 exposed
Issued
Penalty
Initial $2000.00 · Current $1000.00 Reduced
29 CFR 1910.178(p)(1):     Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been taken out of service until restored to safe operating condition(s):    (a)  A Daewoo G25E powered industrial truck was found to be in need of repair of the operator's seat and the LP tank clamps.    (b)  A Datsun powered industrial truck that was available for operation was found to be in need of repair of the LP tank clamps.  The powered industrial truck was also not equipped with a seatbelt.            NO ABATEMENT CERTIFICATION AND DOCUMENTATION REQUIRED
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2000

1910.219 D01

Serious Gravity 5 1 instance 4 exposed
Issued
Penalty
Initial $1700.00 · Current $850.00 Reduced
29 CFR 1910.219(d)(1):     Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o):    (a)  On or about 3/28/13, the feeder machine for the spray operation exposed employees to a rotating pulley while loading product onto the rollers.         NO ABATEMENT CERTIFICATION AND DOCUMENTATION REQUIRED
Recent events (2)
  • — I (S) $850
  • — Z (S) $1700

1910.219 E01 I

Serious Gravity 5 1 instance 4 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.219(e)(1)(i):     Horizontal belts which had both runs 42 inches or less from the floor level were not fully enclosed by guards conforming to requirements specified in 29 CFR 1910.219(m) and (o):    (a) On or about 3/28/13, the feeder for the spray operation exposed employees to an unguarded horizontal belt while loading product onto the rollers.         NO ABATEMENT CERTIFICATION AND DOCUMENTATION REQUIRED
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 G01 IV C

Serious Gravity 5 1 instance 4 exposed
Issued
Penalty
Initial $1600.00 · Current $800.00 Reduced
29 CFR 1910.305(g)(1)(iv)(C):     Flexible cords and cables used were run through doorways, windows, or similar openings:    (a)  An extension cord was run through a doorway to power an internet router near the spray booth located in the northwest end of the facility.           NO ABATEMENT CERTIFICATION AND DOCUMENTATION REQUIRED
Recent events (2)
  • — I (S) $800
  • — Z (S) $1600

1910.178 L06

Other-than-serious 4 instances 4 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.178(l)(6):   The employer did not certify that each operator had been trained and evaluated as required by this paragraph (l):  (a)  The employer did not certify that each operator had been trained and evaluated by documenting the training provided to employees.          NO ABATEMENT CERTIFICATION OR DOCUMENTATION REQUIRED
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View PREFINISHED STAINING PRODUCTS INC.'s full OSHA safety record →