Safety Incidents OSHA Severe Injury Reports · 2015–2025
3,913,242Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: PRECISE FORMS, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of PRECISE FORMS, INC. in 201 NORTH SPRUCE STREET, BATES CITY, MO 64011 (NAICS 331524). OSHA activity number 338980089.

Watch Precise Forms, INC. — free Get an email when a new federal OSHA severe-injury report for Precise Forms, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
PRECISE FORMS, INC.
Site address
201 NORTH SPRUCE STREET
City
BATES CITY
State
MO
ZIP
64011
Mailing
201 NORTH SPRUCE STREET, BATES CITY, MO 64011
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
331524
Employees
53
Ownership type
A

11 citations on file for this inspection.

1910.22 D01

Other-than-serious 2 instances 6 exposed
Issued
Abate by
Penalty
Initial $1785.00 · Current $0.00 Reduced
29 CFR 1910.22(d)(1):     On every building or other structure, or part thereof, used for mercantile, business, industrial or storage purposes, the loads approved by the building official were not marked on plates of approved design and securely affixed in a conspicuous place in each space to which they relate.    (a)  Warehouse:  Employees were exposed to a shelving unit that was over the exit door which did not have a posted load rating.    (b) Window Factory Office and Restrooms:  Employees were exposed to overhead storage above the office and restrooms that did not have a posted load rating.
Recent events (2)
  • — I (O) $0
  • — Z (S) $1785

1910.23 C01

Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $1785.00 · Current $893.00 Reduced
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent) and toeboards:Note:  Toeboards are only required when persons can pass, there is moving equipment or there is equipment with which falling materials could create a hazard.    (a) Window Factory office and restrooms: The storage area above the window factory office and restrooms had a section on the left side of the ladder, that did not have a top rail and mid rail.  To the right side of the ladder, there was a section with no midrail.
Recent events (2)
  • — I (O) $892.5
  • — Z (S) $1785

1910.178 P01

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $1785.00 · Current $0.00 Reduced
29 CFR 1910.178(p)(1):     Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been  taken out of service until restored to safe operating condition(s):    (a) Employees were exposed to the Hyster 80 propane forklift that did not have a functional horn.
Recent events (2)
  • — I (O) $0
  • — Z (S) $1785

1910.179 J02

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $1785.00 · Current $1250.00 Reduced
29 CFR 1910.179(j)(2): The following items were not be inspected for defects at intervals as defined in paragraph (j)(1)(ii) of this section or as specifically indicated, including observation during operation for any defects which might appear between regular inspections:    (a)  There were no frequent inspections of cranes on a daily to monthly interval for hooks with deformation or cracks, hoist chains, functional operating mechanisms for excessive wear of components, and rope reeving, such as, but not limited to, the 1/2 ton Hitachi Electric Crane Hoist in the Tie Shop.
Recent events (2)
  • — I (S) $1249.5
  • — Z (S) $1785

1910.179 J03

Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.179(j)(3): Complete inspections of the crane was not being performed at intervals as generally defined in paragraph (j)(1)(ii)(b) of this section:    (a)Tie Shop:  Cranes, such as, but not limited to the 1/2 ton Hitachi Electric Crane Hoist, did not have periodic inspections on a 1-12 month interval.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.217 D09 IV

Deleted Serious Gravity 5 3 instances 2 exposed
Issued
Abate by
Penalty
Initial $2975.00 · Current $0.00 Reduced
29 CFR 1910.217(d)(9)(iv):   Safety blocks were not used when mechanical power press die(s) were being adjusted or repaired in the press:  (a) Tie Shop: Die blocks provided were shop fabricated and unknown capacity, such as, but not limited to, the die block being used with the Johnson, 250 Ton Press.  Abatement certification is required for this item; use the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET for this purpose.  NOTE: IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM.  FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19
Recent events (2)
  • — I (S) $0
  • — Z (S) $2975

1910.219 C02 I

Other-than-serious 2 instances 2 exposed
Issued
Abate by
Penalty
Initial $2380.00 · Current $0.00 Reduced
29 CFR 1910.219(c)(2)(i): All exposed part(s) of horizontal shafting seven (7) feet or less from floor or working platform were not protected by stationary casing(s) enclosing shafting completely or by trough(s) enclosing sides and top or sides and bottom of shafting:    (a) The horizontal shafting for the Dynamic Feeds feeder for the presses, such as, but not limited to the Johnson Press, was not guarded within seven feet of the floor.
Recent events (2)
  • — I (O) $0
  • — Z (S) $2380

1910.219 C03

Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.219(c)(3): Vertical or inclined shafting seven -7 feet or less from floor or working platform was not enclosed with stationary casing(s):     (a) The vertical shafting for the Dynamic Feeds feeder for the presses, such as, but not limited to the Johnson Press, was not guarded within seven feet of the floor.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1910.303 B02

Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $1785.00 · Current $893.00 Reduced
29 CFR 1910.303(b)(2):     Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:    (a) Machining:  An electrical box with knockouts, such as but not limited to, the electrical box with knockouts being used as a pendant by the Baldor grinder was not used or installed in accordance with listing or labeling instructions.  Electrical boxes with knockouts are to be mounted to a wall or a piece of equipment.
Recent events (2)
  • — I (O) $892.5
  • — Z (S) $1785

1910.305 B02

Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $1785.00 · Current $893.00 Reduced
29 CFR 1910.305(b)(2): Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose:    (a) Tie Shop:  The electrical junction box for the counter by the Hevi Stamper for the Minster Press did not have a cover.
Recent events (2)
  • — I (O) $892.5
  • — Z (S) $1785

1910.305 G02 III

Other-than-serious 3 instances 6 exposed
Issued
Abate by
Penalty
Initial $1785.00 · Current $893.00 Reduced
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws:    (a) Machining:  There was not adequate strain relief to the Baldor Grinder/Buffer.  The outer insulation for the electrical wiring had pulled back at the plug-in exposing interior wiring.    (b) Fab Shop:  The Chicago Press Brake did not have adequate strain relief to the foot pedal.  The outer insulation for the electrical wiring had pulled back at the plug-in exposing interior wiring.    (c) Fab Shop: The Di-Arco Press Brake did not have adequate strain relief to the 2 hand control.  The outer insulation for the electrical wiring had pulled back at the plug-in exposing interior wiring.
Recent events (2)
  • — I (O) $892.5
  • — Z (S) $1785