OSHA Inspection: NEW GENERATION HVAC CONTRACTORS

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of NEW GENERATION HVAC CONTRACTORS in 1900 JOHN ARDEN DR, WAXAHACHIE, TX 75165 (NAICS 238220). OSHA activity number 338993728.

Watch NEW Generation Hvac Contractors — free Get an email when a new federal OSHA severe-injury report for NEW Generation Hvac Contractors is published. One employer, no account, unsubscribe in one click.
Site address
1900 JOHN ARDEN DR
City
WAXAHACHIE
State
TX
ZIP
75165
Mailing
5524 CREEKRIDGE, ARLINGTON, TX 76018
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238220
Employees
15
Ownership type
A

2 citations on file for this inspection.

1926.501 B01

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $1200.00 Reduced
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems.    On or about April 5, 2013, on the west side of the work site, employees were exposed to a fall hazard of approximately 15 feet while installing a roof top unit curb on a commercial building.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2000

1926.503 C

Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $400.00 · Current $240.00 Reduced
29 CFR 1926.503(c): When the employer has reason to believe that any affected employee who has already been trained does not have the understanding and skill required by paragraph (a) of this section, the employer is to retrain each such employee such as inadequacies in an affected employee's knowledge or use of fall protection systems or equipment indicate that the employee has not retained the requisite understanding of skill.   On or about April 5, 2013, on the west side of the work site, employees were exposed to a fall hazard of approximately 15 feet while installing a roof top unit curb of a commercial building.  The employer is to provide retraining to the exposed employees.