HAWTHORNE, NJ —
OSHA Inspection: NORTH VALLEY CONSTRUCTION, LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of NORTH VALLEY CONSTRUCTION, LLC in 148 9TH AVENUE, HAWTHORNE, NJ 07506 (NAICS 238350). OSHA activity number 339049736.
Where did this inspection happen?
- Establishment
- NORTH VALLEY CONSTRUCTION, LLC
- Site address
- 148 9TH AVENUE
- City
- HAWTHORNE
- State
- NJ
- ZIP
- 07506
- Mailing
- PO BOX 1156, WASHINGTON TWPS, NJ 07676
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238350
- Employees
- 3
- Ownership type
- A
Citations
6 citations on file for this inspection.
1926.100 A
- Issued
- Penalty
- Initial $1600.00 · Current $800.00 Reduced
General-duty citation text
29 CFR 1926.100(a): Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, shall be protected by protective helmets. Location: On the side of the house; a) Employees were exposed to head injuries while working without hard hats; on or about 4/2/13.
Recent events (2)
- — I (S) $800
- — Z (S) $1600
1926.451 F06
- Issued
- Penalty
- Initial $1600.00 · Current $800.00 Reduced
General-duty citation text
29 CFR 1926.451(f)(6): The clearance between scaffolds and power lines shall be as follows: Scaffolds shall not be erected, used, dismantled, altered, or moved such that they or any conductive material handled on them might come closer to exposed and energized power lines. Location: Front of house, lower roof. a) Employees were working on a scaffold that was less than ten feet away from an energized power line; on or about 04/02/13.
Recent events (2)
- — I (S) $800
- — Z (S) $1600
1926.451 G01
- Issued
- Penalty
- Initial $2000.00 · Current $1000.00 Reduced
General-duty citation text
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet (3.1 m) above a lower level shall be protected from falling to that lower level. Paragraphs (g)(1)(i) through (vii) of this section establish the types of fall protection to be provided to the employees on each type of scaffold. Paragraph (g)(2) of this section addresses fall protection for scaffold erectors and dismantlers. Note to paragraph (g)(1): The fall protection requirements for employees installing suspension scaffold support systems on floors, roofs, and other elevated surfaces are set forth in subpart M of this part. Location: On pump jack scaffold; side of house. a) Employee was exposed to a fall of approximately 12 ft while working on a pump jack scaffold without any fall protection or fall protection system; on or about 04/02/13.
Recent events (2)
- — I (S) $1000
- — Z (S) $2000
1926.452 J02
- Issued
- Penalty
- Initial $2000.00 · Current $1000.00 Reduced
General-duty citation text
29 CFR 1926.452(j)(2): Poles shall be secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary. When the pump jack has to pass bracing already installed, an additional brace shall be installed approximately 4 feet (1.2 m) above the brace to be passed, and shall be left in place until the pump jack has been moved and the original brace reinstalled. Location: On pump jack scaffold, side of house. a) Employees were accessing a pump jack scaffold with poles that were not secured to the house at the bottom; on or about 04/02/13.
Recent events (2)
- — I (S) $1000
- — Z (S) $2000
1926.1053 B01
- Issued
- Penalty
- Initial $2000.00 · Current $1000.00 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support. Location: Side of the house; a) Employee was exposed to a fall of approximately 12 ft while accessing a scaffold from a ladder that did not extend 3 ft over the landing; on or about 04/2/13.
Recent events (2)
- — I (S) $1000
- — Z (S) $2000
1926.1053 B04
- Issued
- Penalty
- Initial $2000.00 · Current $1000.00 Reduced
General-duty citation text
29 CFR 1926.1053(b)(4): Ladders shall be used only for the purpose for which they were designed. Location: On the side of the house; On or about 04/02/13; a) Employee was using an A frame ladder in the closed position. b) Employee was using the side rail of an extension ladder as a step.
Recent events (2)
- — I (S) $1000
- — Z (S) $2000
More inspections in this industry (NAICS 238350)
JAMESTOWN, RI—2026-07-10 00:00:00
A K I CARPENTRY INC
BROOKLYN, NY—2026-07-08 00:00:00
PALACE RESIDENTIAL CORP.
BROOKLYN, NY—2026-07-07 00:00:00
PRO PROPERTY RENO INC.
KENTON, OH—2026-07-01 00:00:00
SUNLIGHT WINDOWS AND EXTERIORS, LLC
ROBBINSVILLE, NJ—2026-06-30 00:00:00
FAST WRAP WINDOWS & DOORS, INC.
More inspections in NJ
PERTH AMBOY, NJ—2026-07-16 00:00:00
ENGLERT INC.
RIDGEFIELD, NJ—2026-07-16 00:00:00
COLORITE PLASTICS COMPANY
BERLIN, NJ—2026-07-16 00:00:00
URUS CONSTRUCTION CORPORATION
GLASSBORO, NJ—2026-07-15 00:00:00
GLASSBORO WATER & SEWER DEPARTMENT
FLANDERS, NJ—2026-07-15 00:00:00
TRI-STATE QUIKRETE
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339049736.