1,224,460Inspections Most recent open 2026-07-13 Last loaded 2026-07-16
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: JWS REFRIGERATION & AIR CONDITIONING, LTD.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of JWS REFRIGERATION & AIR CONDITIONING, LTD. in 176 MARINE CORPS DRIVE, ASAN, GU 96910 (NAICS 238220). OSHA activity number 339079006.

Watch JWS Refrigeration & AIR Conditioning, LTD. — free Get an email when a new federal OSHA severe-injury report for JWS Refrigeration & AIR Conditioning, LTD. is published. One employer, no account, unsubscribe in one click.
Site address
176 MARINE CORPS DRIVE
City
ASAN
State
GU
ZIP
96910
Mailing
PO BOX 8196, TAMUNING, GU 96931
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238220
Employees
4
Ownership type
A

4 citations on file for this inspection.

1910.37 B02

Serious Gravity 1 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $1200.00 · Current $900.00 Reduced
29 CFR 1910.37(b)(2): Each exit was not clearly visible and marked by a sign reading "Exit":  Warehouse Floor: On May 21, 2013, the employer did not furnish an exit sign over the door from the warehouse into the showroom, exposing employees to a fire hazard.
Recent events (2)
  • — I (S) $900
  • — Z (S) $1200

1910.178 P01

Serious Gravity 1 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $1200.00 · Current $900.00 Reduced
29 CFR 1910.178(p)(1): Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been  taken out of service until restored to safe operating condition(s).   Warehouse Floor: On May 21, 2013, the TCM Brand Forklift Serial Number FVG30N7 front lights, break lights, and emergency break were not operational.
Recent events (2)
  • — I (S) $900
  • — Z (S) $1200

1910.178 Q07

Serious Gravity 1 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.178(q)(7): Industrial trucks were not examined at least daily before being placed in service.  Warehouse Floor: On May 21, 2013, a daily inspection was not conducted on the TCM Brand Forklift Serial Number FVG30N7 with front lights, break lights, and emergency break that were not operational.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 B02 I

Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $1200.00 Reduced
29 CFR 1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy:  Warehouse floor on the wall shared by the showroom: On May 2, 2013, the cover on the electric plug energizing the floor fan was missing, exposing employees to electrical hazards.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $1600