Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: ENPRO TECHNOLOGIES

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ENPRO TECHNOLOGIES in 4225 NE PORT DRIVE, LEES SUMMIT, MO 64064 (NAICS 333318). OSHA activity number 339090821.

Watch Enpro Technologies — free Get an email when a new federal OSHA severe-injury report for Enpro Technologies is published. One employer, no account, unsubscribe in one click.
Establishment
ENPRO TECHNOLOGIES
Site address
4225 NE PORT DRIVE
City
LEES SUMMIT
State
MO
ZIP
64064
Mailing
4225 NE PORT DRIVE, LEES SUMMIT, MO 64064
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333318
Employees
35
Ownership type
A

4 citations on file for this inspection.

1910.178 L01 II

Serious Gravity 10 1 instance 15 exposed
Issued
Abate by
Penalty
Initial $4900.00 · Current $4900.00
29 CFR 1910.178(l)(1)(ii):  The employer did not ensure that each operator had successfully completed the training required by paragraph (l), except as permitted by paragraph (l)(5), prior to permitting an employee to operate a power industrial truck:   (a) On or about May 30, 2013 at the location of 4225 NE Port drive Kansas City, Missouri 64064, employees were exposed to a struck by hazard, when employees were allowed to operate a forklift without training and certification.
Recent events (1)
  • — Z (S) $4900

1910.178 Q07

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.178(q)(7):   Industrial trucks were not examined at least daily before being placed in service:   (a) On or about May 30, 2013 at the facilities located at 4225 NE Port Drive Lee's Summit, Missouri 64064. daily inspection of a TCM OL Series fork truck was not accomplished.
Recent events (1)
  • — Z (S) $0

1910.179 J01 II B

Serious Gravity 10 1 instance 12 exposed
Issued
Abate by
Penalty
Initial $4900.00 · Current $4900.00
29 CFR 1910.179(j)(1)(ii)(b):   Complete inspections of the crane shall be performed at intervals of 1 to 12 months for detecting cracked or deformed members, worn or distorted parts, ie; pins bearing and shafts as well as exessive wear on brakes:  (a) On or about May 5, 2013 at 4225 NE Port Dr Lee's Summit Missouri 64064. Employees in the warehouse were exposed to a struck by hazard from possible failure of hoist because monthly inspections for deformities or cracks were not accomplished or documented.
Recent events (1)
  • — Z (S) $4900

1910.179 J02 III

Serious Gravity 1 1 instance 15 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.179(j)(2)(iii): A certification record which includes the date of inspection, the signature of the person who performed the inspection and the serial number, or other identifier, of the hook inspected, was not maintained:  (a) On or about May 30, 2013 at the location of 4225 NE Port Drive Lees Summit Missouri 64064. Employees in the warehouse were exposed to a struck by hazard from possible failure of control pendants, lift components, cabling, or other mechanisms, because complete inspections of overhead hoists hooks were not performed.
Recent events (1)
  • — Z (S) $0

View ENPRO TECHNOLOGIES's full OSHA safety record →