Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: AMARILLO CUSTOM BOX COMPANY

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of AMARILLO CUSTOM BOX COMPANY in 1501 S. JOHNSON, AMARILLO, TX 79101 (NAICS 322211). OSHA activity number 339112930.

Watch Amarillo Custom BOX Company — free Get an email when a new federal OSHA severe-injury report for Amarillo Custom BOX Company is published. One employer, no account, unsubscribe in one click.
Site address
1501 S. JOHNSON
City
AMARILLO
State
TX
ZIP
79101
Mailing
P.O. BOX 1361, AMARILLO, TX 79105
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
322211
Employees
26
Ownership type
A

11 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 5 6 instances 1 exposed
Issued
Abate by
Penalty
Initial $2380.00 · Current $1428.00 Reduced
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:    On or about June 5, 2013, employees were exposed to unexpected start-up hazards in that the employer did not develop and implement energy control procedures including the following, but not limited to:    a) 50 inch Hooper Press - Serial #WWSG2P911E.    b) 50 inch Press Greene Line Stacker - Serial #1177A2.    c) 50 inch Stanley Flexo - Serial #W6107.    d) 50 inch Koopers Counter Ejector - Serial #1177A2.    e) 35 inch Bostich Flexo - Serial #7879.    f) 35 inch Flexo Printech Counter Ejector - Serial #128.
Recent events (2)
  • — I (S) $1428
  • — Z (S) $2380

1910.212 B

Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $1785.00 · Current $1071.00 Reduced
29 CFR 1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving:    On or about June 5, 2013, employees were exposed to struck by hazards in that the employer did not ensure that a drill press was anchored to the floor.
Recent events (2)
  • — I (S) $1071
  • — Z (S) $1785

1910.215 A04

Serious Gravity 5 2 instances 4 exposed
Issued
Abate by
Penalty
Initial $2380.00 · Current $1428.00 Reduced
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch:    On or about June 5, 2013, employees were exposed to struck-by hazards in that the employer did not ensure that the work rest on the bench grinders were adjusted to the wheel with a maximum opening of one-eighth inch.    a) DeWalt 6" bench grinder, 3450 RPM, 120VAC, 80HZ, Serial #201139-YL-61640, Type 1.    b) Central Machinery 10" bench grinder, 110 volts, 47 amps, 1750 RPM.
Recent events (2)
  • — I (S) $1428
  • — Z (S) $2380

1910.215 B09

Serious Gravity 1 2 instances 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch:    On or about June 5, 2013, employees were exposed to struck by hazards in that the employer did not ensure the bench grinders tongue guard were adjustment to the wheel did not exceed one fourth inch.    a) DeWalt 6" bench grinder, 3550 RPM, 120VAC, 80 HZ, serial #201139-YL-61640    b) Central Machinery 10" bench grinder, 1750 RPM, 110 volts, 47 amps.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.219 D01

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2380.00 · Current $1428.00 Reduced
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o):    On or about June 5, 2013, employees were exposed to caught-in-between hazards in that the employer did not guard a pulley.
Recent events (2)
  • — I (S) $1428
  • — Z (S) $2380

1910.219 E03 I

Serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.219(e)(3)(i): Vertical and inclined belts shall be enclosed by a guard conforming to standards in paragraphs (m) and (o) of this section.     On or about June 5, 2013, employees were exposed to caught-by hazards in that the employer did not ensure that a vertical and incline belt was enclosed by a guard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 B01 IV

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2380.00 · Current $1428.00 Reduced
29 CFR 1910.303(b)(1)(iv): Electric equipment was not free from recognized hazards that were likely to cause serious physical harm to employees, such as damaged electrical insulation:    On or about June 5, 2013, employees were exposed to electric hazards in that the employer did not ensure that a flexible cord on a angle grinder insulation was without damage.
Recent events (2)
  • — I (S) $1428
  • — Z (S) $2380

1910.303 G01 I

Serious Gravity 5 4 instances 3 exposed
Issued
Abate by
Penalty
Initial $2380.00 · Current $1428.00 Reduced
29 CFR 1910.303(g)(1)(i): Work space was less than 30 inches wide in front of electric equipment operating at 600 volts, nominal, or less:    On or about June 5, 2013, employees were exposed to electric hazards in that the employer did not ensure that work space in front of electric panel boxes was not less that 30 inches.    a) General Electric General Duty 480 volts main fire alarm, 480 volts.    b) Fire alarm box in the warehouse, 240 volts.    c) General Electric panel box, the shutoff for the main fire alarm, 480 volts.    d) General Electric panel box, the main shutoff for the fire alarm box, 240 volts.
Recent events (2)
  • — I (S) $1428
  • — Z (S) $2380

1910.304 G05

Serious Gravity 1 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $1785.00 · Current $1071.00 Reduced
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective:    On or about June 5, 2013, employees were exposed to electrical hazards in that the ground prong was missing from the flexible cord of a Lasko fan.
Recent events (2)
  • — I (S) $1071
  • — Z (S) $1785

1910.22 D01

Other-than-serious 2 instances 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.22(d)(1): On every building or other structure, or part thereof, used for mercantile, business, industrial or storage purposes, the loads approved by the building official were not marked on plates of approved design and securely affixed in a conspicuous place in each space to which they relate:  On or about June 5, 2013, employees were exposed to struck by hazards in that the employer did not ensure that a load limit was posted on platforms used for storage.  a) Platform used to store old parts and machinery.  b) Platform above the maintenance shop
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.178 A06

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.178(a)(6): The employer did not ensure that all nameplates or markings were maintained in a legible condition:  On or about June 5, 2013, employees were exposed to struck by hazards in that the employer did not ensure that the nameplate on a Nissan forklift was legible.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View AMARILLO CUSTOM BOX COMPANY's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339112930.