Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,645Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: MCCOY SALVAGE CO. LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of MCCOY SALVAGE CO. LLC in 1301 ADAMS AVENUE, CARUTHERSVILLE, MO 63830 (NAICS 423930). OSHA activity number 339116386.

Watch Mccoy Salvage CO. LLC — free Get an email when a new federal OSHA severe-injury report for Mccoy Salvage CO. LLC is published. One employer, no account, unsubscribe in one click.
Site address
1301 ADAMS AVENUE
City
CARUTHERSVILLE
State
MO
ZIP
63830
Mailing
P.O. BOX 255, CARUTHERSVILLE, MO 63830
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
423930
Employees
9
Ownership type
A

4 citations on file for this inspection.

1910.212 A05

Serious Gravity 5 2 instances 6 exposed
Issued
Abate by
Penalty
Initial $1760.00 · Current $880.00 Reduced
29 CFR 1910.212(a)(5): Fan blade guard(s) were not provided where the periphery of the blades was less than seven feet from the floor or working level:    At the time of the inspection, two cooling fans were operated without guards. A floor fan was operated without a rear guard and a "Porta Cool" unit was operated with the front guard removed.    Abatement certification and abatement documentation is required for this violation.  The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos which you believe will be helpful.  The abatement certification sheet is enclosed with the citations.
Recent events (2)
  • — I (S) $880
  • — Z (S) $1760

1910.219 D01

Serious Gravity 5 2 instances 5 exposed
Issued
Abate by
Penalty
Initial $1760.00 · Current $880.00 Reduced
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o):    At the time of the inspection the following pulleys were not guarded;    a) The drive pulley for the floor fan.  b) The drive pulleys for the air compressor.     Abatement certification and abatement documentation is required for this violation.  The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos which you believe will be helpful.  The abatement certification sheet is enclosed with the citations.
Recent events (2)
  • — I (S) $880
  • — Z (S) $1760

1910.147 C04 I

Repeat Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $4400.00 · Current $2200.00 Reduced
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:    At the time of the inspection, lockout procedures were not utilized when employees were replacing a bolt in the ram of the Fox baler. The power supply to the controls on the ram were not locked to prevent the un-expected energization and startup of the hydraulic system including the ram.     The McCoy Salvage Co. Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1910.147(c)(4)(i), which was contained in OSHA inspection number 315249334 citation number 1, item number 6b and was affirmed as a final order on 4/2/2011, with respect to a workplace located at 1301 Adams Ave, Caruthersville, MO.
Recent events (2)
  • — I (R) $2200
  • — Z (R) $4400

1910.305 B01 II

Repeat Gravity 10 5 instances 9 exposed
Issued
Abate by
Penalty
Initial $6160.00 · Current $3080.00 Reduced
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:    At the time of the inspection the following openings were found;    a) The circuit breaker panel box was missing multiple breakers at the northeast corner of the metal processing building.  b) The junction box above the shear had an opening that was not covered.  c) The disconnect box at the shear was damaged.  d) The motor for the Densor 600 was missing the cover.  e) The air compressor switch was not covered.      The McCoy Salvage Co., was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1910.305(b)(1)(ii) which was contained in OSHA inspection number 315249334, citation number 1, item number 9a and was affirmed as a final order on 4/2/2011, with respect to a workplace located at 1301 Adams Ave. Caruthersville, MO.
Recent events (2)
  • — I (R) $3080
  • — Z (R) $6160