WOBURN, MA —
OSHA Inspection: EXTERIOR SOLUTIONS
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of EXTERIOR SOLUTIONS in 132 PLEASANT STREET, WOBURN, MA 01801 (NAICS 238170). OSHA activity number 339126831.
Where did this inspection happen?
- Establishment
- EXTERIOR SOLUTIONS
- Site address
- 132 PLEASANT STREET
- City
- WOBURN
- State
- MA
- ZIP
- 01801
- Mailing
- 17 TADMUCK ROAD, CHELMSFORD, MA 01824
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238170
- Employees
- 4
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.304 I01
- Issued
- Abate by
- Penalty
- Initial $1600.00 · Current $960.00 Reduced
General-duty citation text
29 CFR 1926.304(i)(1): Each circular hand-fed ripsaw shall be guarded by a hood which shall completely enclose the portion of the saw above the table and that portion of the saw above the material being cut. The hood and mounting shall be arranged so that the hood will automatically adjust itself to the thickness of and remain in contact with the material being cut but it shall not offer any considerable resistance to insertion of material to saw or to passage of the material being sawed. The hood shall be made of adequate strength to resist blows and strains incidental to reasonable operation, adjusting, and handling, and shall be so designed as to protect the operator from flying splinters and broken saw teeth. It shall be made of material that is soft enough so that it will be unlikely cause tooth breakage. The hood shall be so mounted as to insure that its operation will be positive, reliable, and in true alignment with the saw; and the mounting shall be adequate in strength to resist any reasonable side thrust or other force tending to throw it out of line. (a) Location - Pleasant Street, Woburn, MA: Onor about 6/19/13, the employer failed to ensure that a Ryobi 10-inch table saw was adequately guarded.
Recent events (2)
- — I (S) $960
- — Z (S) $1600
1926.403 B02
- Issued
- Abate by
- Penalty
- Initial $1600.00 · Current $960.00 Reduced
General-duty citation text
29 CFR 1926.403(b)(2): Installation and use. Listed, labeled, or certified equipment shall be installed and used in accordance with instructions included in the listing, labeling, or certification. (a) Location - Pleasant Street, Woburn, MA: On or about 6/19/13, electrical equipment was not used in accordance with its labeling and listing (relocatable power taps).
Recent events (2)
- — I (S) $960
- — Z (S) $1600
1926.451 G01
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $1080.00 Reduced
General-duty citation text
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet (3.1 m) above a lower level shall be protected from falling to that lower level. Paragraphs (g)(1)(i) through (vii) of this section establish the types of fall protection to be provided to the employees on each type of scaffold. Paragraph (g)(2) of this section addresses fall protection for scaffold erectors and dismantlers. (a) Location - Pleasant Street, Woburn, MA: On or about 6/19/13, the employer failed to ensure that each employee on a scaffold 10 or more feet above a lower level was provided with fall protection.
Recent events (2)
- — I (S) $1080
- — Z (S) $2000
1926.452 J02
- Issued
- Abate by
- Penalty
- Initial $1600.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.452(j)(2): Poles shall be secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary. When the pump jack has to pass bracing already installed, an additional brace shall be installed approximately 4 feet (1.2 m) above the brace to be passed, and shall be left in place until the pump jack has been moved and the original brace reinstalled. (a) Location - Pleasant Street, Woburn, MA: On or about 6/19/13, the employer failed to ensure that pump jack scaffold poles were secured to the structure at the bottom.
Recent events (2)
- — I (S) $0
- — Z (S) $1600
More inspections at EXTERIOR SOLUTIONS
OCEAN SPRINGS, MS—2018-03-28 00:00:00
EXTERIOR SOLUTIONS
DENVER, CO—2014-05-28 00:00:00
EXTERIOR SOLUTIONS
WASHINGTON, DC—2011-03-29 00:00:00
EXTERIOR SOLUTIONS
SHERBORN, MA—2010-04-08 00:00:00
EXTERIOR SOLUTIONS
View EXTERIOR SOLUTIONS's full OSHA safety record →
More inspections in this industry (NAICS 238170)
OXFORD, OH—2026-07-13
R&R SIDING LLC
WINSTON SALEM, NC—2026-07-10
161522 - MS SIDING LLC
SLINGER, WI—2026-07-10
DYLAN MATTHEW SHELLEY LLC
WINSTON SALEM, NC—2026-07-09
161514 - ALPHA OMEGA CONSTRUCTION GROUP, INC
ATLANTA, GA—2026-07-09
ESV CONSTRUCTION LLC
More inspections in MA
WORCESTER, MA—2026-07-10
QUINSIGAMOND COMMUNITY COLLEGE