Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: PINE HILL BUILDERS, LLC.

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of PINE HILL BUILDERS, LLC. in 23 CHURCH STREET, TREMONT, PA 17981 (NAICS 236115). OSHA activity number 339173510.

Watch Pine Hill Builders, LLC. — free Get an email when a new federal OSHA severe-injury report for Pine Hill Builders, LLC. is published. One employer, no account, unsubscribe in one click.
Site address
23 CHURCH STREET
City
TREMONT
State
PA
ZIP
17981
Mailing
2070 BEAVER DAM ROAD, HONEY BROOK, PA 19344
Inspection type
Unprogrammed Other (I)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236115
Employees
3
Ownership type
A

3 citations on file for this inspection.

1926.95 A

Serious Gravity 1 1 instance 2 exposed
Issued
Penalty
Initial $1200.00 · Current $750.00 Reduced
29 CFR 1926.95(a): Protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers, were not provided, used, and maintained in a sanitary and reliable condition:     a) 23 Church Street, Tremont, PA; Employees were operating a nail gun to install roofing shingles without the use of safety glasses, on or about 07/10/2013.        Abatement Observed During Inspection - No Abatement Certification Required
Recent events (2)
  • — I (S) $750
  • — Z (S) $1200

1926.501 B13

Serious Gravity 5 2 instances 2 exposed
Issued
Penalty
Initial $1600.00 · Current $1000.00 Reduced
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):     a) 23 Church Street, Tremont, PA, Front Side Area; Employees were installing roofing shingles on a 6/12 pitch roof 20 feet above the ground without the use of fall protection, on or about 07/10/2013.        b) 23 Church Street, Tremont, PA, Back Side Area; Employees were installing roofing shingles on a 6/12 pitch roof 10 feet above the ground without the use of fall protection, on or about 07/10/2013.        Abatement Observed During Inspection - No Abatement Certification Required
Recent events (2)
  • — I (S) $1000
  • — Z (S) $1600

1926.1053 B01

Serious Gravity 1 1 instance 2 exposed
Issued
Penalty
Initial $1200.00 · Current $750.00 Reduced
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to upper landing surfaces, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladders were used to gain access:     a) 23 Church Street, Tremont, PA; Employees were using a Werner D028-2 extension ladder to access the roof that was not 3 feet above the landing, on or about 07/10/2013.        Abatement Observed During Inspection - No Abatement Certification Required
Recent events (2)
  • — I (S) $750
  • — Z (S) $1200

View PINE HILL BUILDERS, LLC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339173510.