OSHA Inspection: MATAFIED EXTERIOR AND INTERIOR

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of MATAFIED EXTERIOR AND INTERIOR in 3200 N RICHMOND STREET, APPLETON, WI 54911 (NAICS 238160). OSHA activity number 339182750.

Watch Matafied Exterior AND Interior — free Get an email when a new federal OSHA severe-injury report for Matafied Exterior AND Interior is published. One employer, no account, unsubscribe in one click.
Site address
3200 N RICHMOND STREET
City
APPLETON
State
WI
ZIP
54911
Mailing
410 E KIMBERLY AVENUE, KIMBERLY, WI 54136
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
2
Ownership type
A

5 citations on file for this inspection.

1926.501 B10

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $2000.00
29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system:   a)  On 07-12-13, employees were working on a 4:12 pitch roof with an eave edge greater than nine and one half (9.5) feet above compacted surface without utilizing fall protection equipment.   ABATEMENT CERTIFICATION REQUIRED
Recent events (1)
  • — Z (S) $2000

1926.503 A02 VIII

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.503(a)(2)(viii): The employer did not assure that each employee had been trained by a competent person qualified in the standards contained in subpart M:   a)  On or before 07-12-13, the employer did not provide employee fall protection safety training for employees who did not associate fall from elevation hazards with working on a roof with an eave edge greater than nine and one half (9.5) feet above compacted surface without using fall protection equipment.  ABATEMENT CERTIFICATION REQUIRED
Recent events (1)
  • — Z (S) $0

1926.1053 B01

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $2000.00
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:   a)  On 07-12-13, employees were using a non-self-supporting sixteen ft. extension ladder to access a roof surface with the side rails extended less than two (2) feet above the upper landing surface.  ABATEMENT CERTIFICATION REQUIRED
Recent events (1)
  • — Z (S) $2000

1926.1053 B21

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.1053(b)(21): Employees were not grasping the ladder with at least one hand when progressing up and/or down the ladder:   a)  On 07-12-13, employees who were tearing off shingles were carrying roofing debris while descending a non self-supporting sixteen ft. extension ladder without three points of contact on the ladder.   ABATEMENT CERTIFICATION REQUIRED
Recent events (1)
  • — Z (S) $0

1926.1060 A01 V

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.1060(a)(1)(v): The employer did not ensure that each employee using ladders and/or stairways had been trained by a competent person in the standards contained in Subpart X:   a)  On or before 07-12-13, the employer did not provide employee ladder safety training for employees who did not associate fall from elevation hazards with utilizing a sixteen (16) ft. extension ladder to access/egress a roof surface with grabrails less than two feet above the upper landing and with descending the ladder without three points of contact.  ABATEMENT CERTIFICATION REQUIRED
Recent events (1)
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339182750.