Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: MAUI VENTURE LP

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of MAUI VENTURE LP in 658 WHARF STREET, LAHAINA, HI 96761 (NAICS 721110). OSHA activity number 339223380.

Watch Maui Venture LP — free Get an email when a new federal OSHA severe-injury report for Maui Venture LP is published. One employer, no account, unsubscribe in one click.
Establishment
MAUI VENTURE LP
Site address
658 WHARF STREET
City
LAHAINA
State
HI
ZIP
96761
Mailing
100 CRESCENT COURT SUITE 155, DALLAS, TX 75201
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
721110
Employees
43
Ownership type
A

7 citations on file for this inspection.

1910.36 D01

Serious Gravity 5 1 instance 4 exposed
Issued
Penalty
Initial $2023.00 · Current $1517.00 Reduced
29 CFR 1910.36(d)(1): Employee(s) were not able to open an exit route door from the inside at all times without keys, tools, or special knowledge:  (a)  Kitchen:  On July 17, 2013, the walk-in freezer door would not open from the inside.
Recent events (2)
  • — I (S) $1517.25
  • — Z (S) $2023

1910.215 A04

Serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $1785.00 · Current $1339.00 Reduced
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch:   (a)  Maintenance Shop:  On July 17, 2013, and at times prior thereto, the left work rest on the Delta 6-Inch Thin-Line Bench Grinder, Model  23-660, was approximately one-half inch from the grinding wheel.
Recent events (2)
  • — I (S) $1338.75
  • — Z (S) $1785

1910.305 B02 I

Serious Gravity 1 2 instances 2 exposed
Issued
Penalty
Initial $1517.00 · Current $1138.00 Reduced
29 CFR 1910.305(b)(2)(i): Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose:  (a)  Maintenance Shop:  On July 17, 2013, and at times prior thereto, a junction box on the southeast wall did not have a cover and energized conductors were exposed.  (b)  Maintenance Shop:  On July 17, 2013, and at times prior thereto, an outlet on the northwest wall did not have a faceplate and energized conductors were exposed.
Recent events (2)
  • — I (S) $1137.75
  • — Z (S) $1517

1910.305 J01 I

Serious Gravity 1 1 instance 1 exposed
Issued
Penalty
Initial $1517.00 · Current $1138.00 Reduced
29 CFR 1910.305(j)(1)(i): Fixtures, lampholders, lamps, rosettes, and receptacles located within 8 feet of the floor had live parts exposed to employee contact:   (a)  Maintenance Shop:  On July 17, 2013, and at times prior thereto, the florescent light fixture above the work bench and approximately 84 inches (7 feet) above the ground was not guarded to prevent damage and contact with the electrical components.
Recent events (2)
  • — I (S) $1137.75
  • — Z (S) $1517

1910.333 B02 I

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2975.00 · Current $2231.00 Reduced
29 CFR 1910.333(b)(2)(i): The employer did not maintain a written copy of the procedures outlined in paragraph (b)(2) of 29 CFR 1910.333 and did not make it available for inspection by the Assistant Secretary of Labor and his or her authorized representatives:  (a)  Facility Wide:  On July 17, 2013, and at times prior thereto, written electrical safe work practice procedures had not been developed by the work site.
Recent events (2)
  • — I (S) $2231.25
  • — Z (S) $2975

1910.333 B02 III A

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.333(b)(2)(iii)(A): A lock and a tag were not placed on each disconnecting means used to deenergize circuits and equipment on which work was to be performed:   (a) Maintenance Operations:  On July 17, 2013, and at times prior thereto, locks and tags were not placed on electrical disconnects when employees were repairing and/or replacing electrical switches and fixtures.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.157 E02

Other-than-serious 1 instance 43 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.157(e)(2): Portable fire extinguishers were not visually inspected at least monthly:  (a)  Throughout Facility:  On July 17, 2013, and at times prior thereto, the employer had not established a procedure to visually inspect the portable fire extinguishers. There are approximately 30 portable fire extinguishers located throughout the facility.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339223380.